Is the backup heating temperature sensor deep enough in
the immersion sleeve?
If not, insert the sensor correctly.
Is your water high in limescale?
If you suspect that the heat exchanger is coated with
limescale (inside), please call your installer to check
and delime it if necessary (see maintenance). To check
the heat exchanger, the clamping screw fitting of the
hot water connection can be opened and the now open
heat exchanger pipe can be inspected as a result. The
heat exchanger should be delimed from a lime coating
of 0.5 mm.
10.2
The heating temperatures are too low
Please check:
Is the temperature sensor for the heating buffer area in the
immersion sleeve at the level of the heating supply?
10.3
The storage tank cools down quickly
Please check:
Are all connected pipes (solar, boiler , cold and hot water)
at ambient temperature during standstilll?
If not, please ask your installer to conduct testing (and if
necessary, installation) of non-return valves.
Is the insulation in close contact with the floor?
If not, seal the gap.
If, despite all of these measures, the hot water tempera-
tures in the technical data of the SOLUS II cannot be
achieved, please call your installation company.
INFORMATION:
The statements made in the technical documentation
and the information provided do not lay claim to com-
pleteness and do not replace professional planning.
Changes and errors reserved.
Technical hotline:
0700-CONSOLAR
(0700-26676527)
In Germany, normal Deutsche Telekom
rate
CONSOLAR products and advice are obtainable at:
Consolar Solare
Energiesysteme GmbH
Department Solar Heating
Systems
Strubbergstraße 70
D - 60489 Frankfurt
Germany Phone:
Fon: 0049 69-7409328-0
Fax: 0049 69-7409328-50
[email protected]
www.consolar.com
Last revised 05/2009
, Changes and errors reserved.