TD SOLUS II:
11
La
st
r
ev
is
ed
0
5/
20
0
9
5.3
Connection examples for parallel connection
5.3.1
Boiler buffering
Boiler
HS
>30°C R1/2
<30°C R3
BS
Heating Circuit
50/35
SOLUS
SOLUS or
Buffer module
BS1
Example 10: Heating circuit 50/35, oil boiler
5.3.2
Return increase
Boiler
HS
>30°C R1/2
<30°C R3
BS
Heating Circuit
50/35
SOLUS
SOLUS or
Buffer module
BS 1
Example 11: Heating circuit 50/35, oil or gas boiler
5.3.3
Parallel connection of the heat exchangers of two
SOLUS II storage tanks
CW
CW
HW
HW
Solar hot
Solar cold
SOLUS
SOLUS
Example 12: Connections for water and the solar power
system
1)
On the SOLUS II 1050 L and SOLUS II 2200 L the cold water con-
nection is under the solar cold connection.
5.4
Connection example for cascade connection
For solid fuel boilers, the buffer volume can be increased
with a buffer module by cascade connection of a SOLUS.
The buffer module is charged by the solid fuel boiler and
discharged by the heating circuit. The solar power system
charges the SOLUS, which is discharged via hot water tap-
ping, with the result that the buffer module remains cold in
the summer.
Boiler
HS
>30°C R1/2
<30°C R3
BS
Heating Circuit
50/35
SOLUS
Buffer module
HS
R1/2
R3
BS
BS 1
Example 13