13
4. Cut a piece of fiber optic cable 15' (5 m)long. This is your test piece of cable.
5. Install the correct size Venturi to fit the cable being installed. (Figure 8)
6. Attach the Air Hose. The Gulfstream™ 350’s air system uses a Universal Claw (Figure
27) fitting(US). Take caution in routing the hose to prevent a tripping hazard. Follow
these steps to connect the air hose:
A. Attach the Universal claw fitting to the compressor to the machine. (Figure 9)
Make sure valve is in off or exhaust position. (Figure 10)
B. Start the compressor and check all connections for leaks . In cold weather, run
compressor until it is warmed up. Observe the following precautions to avoid
pnuematic hazards:
• Tighten all connections before applying pressure. Relieve pressure before
connecting or disconnecting hose.
• Do not exceed working pressure of pneumatic hose (not supplied). Visually
inspect hose regularly and replace if damaged.
Figure 9. Attach Claw Fitting
Figure 10. Air Valve
Figure 8. Install Venturi