![Condair GS 120 OC Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/condair/gs-120-oc/gs-120-oc_installation-commissioning-and-service-instructions_2651722057.webp)
57
Replacing the transformer
1. Take the humidifier out of operation, as described in chapter 7.4.
2. Undo the brackets and open the right front panel
3. Remove the connection cables to the transformer, if necessary labeling the cables before removal.
4. Unscrew the two nuts and remove he transformer.
Reinstallation is carried out in the reverse sequence. Make sure the cables are connected correctly.
Replacing the drain pump
1. Take the humidifier out of operation, as described in chapter 7.4.
Important! If drain pump is defective, drain tank manually via the auxiliary drain.
2. Undo the brackets and open the right side panel.
3. Remove the connection cables to the drain pump (note assignment before removal).
4. Remove hose clamps on the drain pump connections and pull off the hoses, then remove the drain
pump.
Reinstallation is carried out in the reverse sequence. Make sure the hoses are correctly secured with
the hose clamps and the cables are connected correctly.