103
EN
SVK6550ss / SVK6550wh
Fig.11
4. Mount the burner knob.
5. Make sure that the flame does not go out by quickly turning from maximum flow to minimum flow. If it
does, pull the knob to remove it, readjust the minimum flame height and perform another check.
6. Adjust the minimum flame height for all burners.
Note:
1. Do not disassemble the valve shaft. In the event of a malfunction, change the whole valve.
2. Before mounting all burner parts, make sure that the nozzles are not clogged.
3. After replacing burner nozzles for a different gas type, it is necessary to perform a full operation test and
leakage test.
SERVICING
Replacing a bulb
To illuminate the interior of the appliance, a halogen bulb of high thermal
resistance is used (25–40 W/220–240 V, T300 °C).
To remove the bulb proceed as follows:
1. Disconnect the appliance from the power supply, or switch off the appropri-
ate circuit breaker.
2. Unscrew the glass cover in the anti-clockwise direction according to Fig. 11
and replace the bulb with a bulb of the same type and parameters.
3. When installing a new bulb, use a rag or paper wipe to hold the bulb.
4. Re-install the glass cover.