102
EN
SVK6550ss / SVK6550wh
Fig. 10
Adjusting screw
REPLACEMENT OF NOZZLES AND ADJUSTMENT OF THE MINIMUM
FLAME HEIGHT
Replacement of burner nozzles and adjustment of the minimum flame height may be performed only by
a qualified professional or authorized service personnel.
Replacement of burner nozzles
1. Close the gas supply and pull out the plug from the electrical socket.
2. Remove the burner grate, burner cover and flame spreader.
3. Unscrew the nozzle using a 7mm socket spanner and replace it with a nozzle for a different gas type.
Firmly tighten the nozzle.
4. Reassemble all parts of the burner (flame spreader, cover and grate).
Adjustment of minimum flame height
The gas supply to the surface burners is opened and adjusted by taps with anti-
leakage protection.
The taps must be adjusted with the burner lit in position - energy saving flame,
using a 2.5mm adjusting screwdriver.
1. Ignite the respective burner and turn the burner knob to the minimum
position (MIN).
2. Pull the knob to remove it.
3. The ideal minimum flame height should be 3–4 mm. When using
propane-butane, screw in the adjustment screw almost completely.
Fig. 9