Removal
To uninstall the unit, it is important to proceed correctly:
1. First, switch off the circuit breaker and unplug the mains cable from the socket.
2. Remove the retaining clips.
3. Take out the hob and at the same time pull out the mains cable carefully.
Connecting to the mains power
•
Only a qualified person can install this appliance!
•
Make sure that the parameters on the rating plate are compatible with the electrical ratings of the main power
supply.
•
Make sure that the parameters on the rating plate are compatible with the mains voltage and
the current
protection.
Otherwise the installed electric circuit could be overloaded, especially in the case of single-phase
connection (230 V).
•
If the hob is connected to the mains power in a single phase (see Connection of the terminal box of the appliance), all
cooking zones cannot be used for maximum performance. The hob automatically reduces the power consumption
of individual cooking zones to avoid overloading of the circuit breaker.
Sealing
Fig. 10
Hob
Retaining clip
Worktop
Fig. 9
L1
L
N
L2
N1
N2
L-N:220-240V ~
Brown
Black
Blue
Grey
PE