2:23
UGG050-0517
S Series
Advanced
C I R C U I T
B R E A K E R
T R I P P E D
Basic
(B)
Extended
(A)
(C)
(C)
(C)
DESCRIPTION
(A) = Reset button, Basic
(B) = Reset knob, Extended / Advanced
(C) = The overload protection has tripped
Overload protection, Motor
General rules, Overload protection
The machine can be provided with several overload
protections. The overload protection(s) is/are installed
inside the electrical cabinet. The electrical circuit diagram
shows the number of overload protections installed in the
supplied machine.
The overload protection trips if the granulator or any
optional equipment is overloaded.
Overload is indicated and reset in different ways depend-
ing on type of electrical cabinet. >Page 2:18 “Electrical
cabinet, Operating panel”.
Note! Before resetting an overload protection and before
restarting the machine, the reason why the overload
protection tripped must be determined. Take necessary
actions (for example clean the machine) to prevent the
overload protection from immediate tripping when
restarting the machine.
Basic
Overload is indicated by the red warning lamp. The
overload protection is reset by pressing the reset button.
Note! Red light can also indicate metal detection.
>Page 2:25 “IMD-system”.
Extended
Overload is indicated by the red warning lamp. The
overload protection is reset by turning the reset knob
inside the electrical cabinet.
Advanced
Overload is indicated by the red warning lamp and a fault
message on the display. The overload protection is reset
by turning the reset knob inside the electrical cabinet.
2. DESCRIPTION