160 - Troubleshooting and Technical Support
DeviceMaster PNIO | UP User Guide
: 2000639 Rev. A
Troubleshooting and Technical Support
Technical Support
If you need technical support use one of the following methods.
2
PNIO-2102
PNIO-2202
PNIO-2302
PNIO-2402
•
The
STATUS
LED on the device is lit, indicating you have power
and it has completed the boot cycle.
Note:
The
STATUS
LED flashes while booting and it takes
approximately 15 seconds for the Bootloader to complete
the cycle.
When the Bootloader completes the cycle, the
LED flashes rapidly for several times then stays off and
blinks approximately every 10 seconds when there is no
PLC connection
.
•
If the
LINK
(green) LED is lit, it indicates a working Ethernet
connection.
•
If the
ACT
(yellow) LED flashes, it indicates network activity.
4
DIN
Rail
PNIO-2304
•
The
STATUS
LED on the device is lit, indicating you have power
and it has completed the boot cycle.
Note:
The
STATUS
LED flashes while booting and it takes
approximately 15 seconds for the Bootloader to complete
the cycle.
When the Bootloader completes the cycle, the
LED flashes rapidly for several times then stays off and
blinks approximately every 10 seconds when there is no
PLC connection
.
•
If the
LINK
(green) LED is lit, it indicates a working Ethernet
connection.
•
If the
ACT
(yellow) LED flashes, it indicates network activity.
4
Panel
Mount
DeviceMaster
UP†
•
The
PWR
LED
on the front of the unit is lit, which indicates it
has power and has completed the boot cycle.
Note:
The
PWR
LED flashes while booting and it takes
approximately 15 seconds for the Bootloader to complete
the cycle.
When the Bootloader completes the cycle, the
LED flashes rapidly for several times then stays off and
blinks approximately every 10 seconds when there is no
PLC connection
.
•
The red
LNK/ACT
LED is lit, which indicates a working
Ethernet connection.
•
If the red
100
LED is lit, it indicates a working 100 MB Ethernet
connection (100 MB network, only).
Ports
Model
Network LEDs
Comtrol Contact Information
Downloads (FTP)
ftp://ftp.comtrol.com/html/DM_UP_Main.htm
Downloads (HTTP)
http://downloads.comtrol.com/html/DM_UP_Main.htm
Web site
Phone
(763) 957-6000
Содержание 99531-9
Страница 1: ...PROFINET IO User Guide ...
Страница 60: ...60 Configuring a Serial Port DeviceMaster PNIO UP User Guide 2000639 Rev A Configuring a Serial Port ...
Страница 88: ...88 IO Data Handling DeviceMaster PNIO UP User Guide 2000639 Rev A IO Data Handling ...
Страница 138: ...138 Managing the DeviceMaster DeviceMaster PNIO UP User Guide 2000639 Rev A Managing the DeviceMaster ...
Страница 148: ...148 RedBoot Procedures DeviceMaster PNIO UP User Guide 2000639 Rev A RedBoot Procedures ...