TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–31
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Remote
Address
SPA=
4 bytes
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example:
<1/SPA=0412’cr’
>0001/SPA=’cr’’lf’
Default Value: 0001
SPA=
SPA?
SPA=xxxx
(Same
format as
command
arguments)
Set Serial
Format
SPB=
3 bytes
Command or Query.
Set the Serial Data Bits, Parity, and Stop Bits.
Format: XYZ with valid combinations of 8N1, 7E2, and 7O2.
Where:
X = Serial Data Bits (7 or 8)
Y = Parity (N = None, E = Even, O = Odd)
Z = Stop Bits (1 or 2)
Example:
<1/SPB=7E2’cr’
>0001/SPB=’cr’’lf’
Default Value: 8N1
SPB=
SPB?
SPB?
SPB=XYZ
(Same
format as
command
arguments)
SNMP Read
Community
SRC=
16 bytes,
characters,
no spaces
Command or Query.
SNMP read community string. Empty string is not allowed
Example:
<1/SRC=public
SRC =
SRC!
SRC?
SRC =x
(See
description
of
arguments)
SNMP
System
Contact
SSC=
255 bytes,
characters
Command or Query.
SNMP System Contact string.
Example:
<1/SSC=Joe Net Admin
If not configured, it returns empty string: <1/SSC=
SSC =
SSC!
SSC?
SSC =x
[1..128]
(See
description
of
arguments)