TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–33
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
SNMP Trap
Destination
IP Address 2
STB=
15 bytes,
Numerical
Command or Query.
Used to set the IP address of the first SNMP Trap destination
IP Address 2
Where
traps will be sent, in the form:
xxx.xxx.xxx.xxx is the IP addresss
Example:
<1/STB=010.006.030.001
When not configured, returns >0001/STB=0.0.0.0
STB =
STB!
STB?
STB=xxx.xx
x.xxx.xxx
(See
description
of
arguments)
SNMP
Trap Version
STV=
1 byte
Command or Query.
SNMP Trap Version that will be used to send traps.
1=SNMP Trap Version 1
2=SNMP Trap Version 2
Example:
<1/STV=0
STV =
STV!
STV?
STV =x
(See
description
of
arguments)
SNMP
Write
Community
SWC=
16bytes,
characters,
no spaces
Command or Query.
SNMP write community string. Empty string is not allowed
Example:
<1/SWC=private
SWC =
SWC!
SWC?
SWC =x
(See
description
of
arguments)
Set RTC
Time
TIM=
6 bytes
Command or Query.
A command in the form
hhmmss
, indicating the time from
midnight, where hh = hours, between 00 and 23; mm =
minutes, between 00 and 59, and ss = seconds, between 00
and 59
Example
(time = 23 hours, 12 minutes and 59 seconds since
midnight):
<1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
TIM =
TIM?
TIM *
TIM?
TIM=xxxxxx
(Same
format as
command
arguments)