TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–17
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Low forward
Power
Threshold
LPT=
5 bytes
Command or Query.
This command allows the user to set the threshold for the
low forward power alarm/fault. If the forward power drops
below the specified value, the alarm/fault will be indicated.
Setting this parameter to 00.00 effectively disables the
threshold.
Example:
<0001/LPT=00.00’cr’
>0001LPT=’cr’’lf’
Default Value: 00.00
LPT =
LPT?
LPT *
LPT?
LPT =xxx.x
(Same
format as
command
arguments)
Local
Remote State
LRS=
1 byte
Command or Query.
Set Local or Remote for Indoor SSPA. Always in remote
mode for Outdoor SSPA
1=Serial, 2=Ethernet, 3=Ethernet
Example:
<1/LRS=3’cr’
>0001/LRS=’cr’’lf’
Note:
The user will always have query access in any mode.
Also, the LRS command is available in all modes as a
means of acquiring control. The intent of this
command is to limit changes from being made on
multiple interfaces at the same time. The web page
GUI will refuse connections unless LRS is set to
enable Ethernet remote control.
Default Value: 3 (Ethernet)
LRS=
LRS?
LRS?
LRS=x
(Same
format as
command
arguments)
Unit MAC
Address
N/A
17 bytes
Query only.
MAC address of the unit, reported in hexadecimal.
Example:
<0001/MAC?’cr’
>0001/MAC=00-06-B0-00-D2-A7’cr’’lf’
MAC=
MAC?
MAC=xx-xx-
xx-xx-xx-xx
(See
description
for details of
arguments)