SMS-758 Modem Protection Switch
Installation
MN/SMS758 Rev. 3
2–3
2.2.2 Modem Setup
J28 through J35 are the eight IF outputs available to connect to the customer-supplied
uplink power combiners.
J7 through J10, and J12 through J15, are the downlink inputs available for use with up to
eight customer-supplied downlink splitters. The following steps describe the uplink and
downlink connections:
1. Connect the IF output cables 1 through 8 to the appropriate customer-furnished
uplink signal combiner inputs.
2. Connect the downlink input cables 1 through 4, or 1 through 7, to the appropriate
customer-furnished downlink splitters.
3. When using the 7 downlink option, connect J16 (backup 2 output) to J7, and
specify 7 downlinks/1 backup in the System menu.
Note: Be sure to terminate all unused IF outputs and downlink inputs with the
supplied 75
Ω
BNC terminations.
2.3 System Requirements
The switch, with all interface assemblies installed (Figure 2-1), is capable of operating as
a 2:8 protection switch. This means that two full-duplex standby modems back up eight
full-duplex primary modems.
Note: When IDR interface AS/0895 is used, only one backup is available.
The switch can be configured in any combination including:
•
TX only modems.
•
RX only modems.
•
Mixed interfaces (limited to two).
•
Multiple uplinks (limited to eight).
•
Multiple downlinks (limited to four with 2 backups, 7 with 1 backup).
•
Multiple data rate and code rate operation.
•
Refer to Section 3.2 for a complete explanation of the configuration function.
Содержание SMS-758
Страница 2: ......
Страница 16: ...Table of Contents SMS 758 Modem Protection Switch xii MN SMS758 Rev 3 This page is intentionally left blank...
Страница 20: ...Introduction SMS 758 Modem Protection Switch 1 4 MN SMS758 Rev 3 Figure 1 2 System Block Diagram...
Страница 23: ...SMS 758 Modem Protection Switch Introduction MN SMS758 Rev 3 1 7 Figure 1 5 SMS 758 Block Diagram...
Страница 28: ...Introduction SMS 758 Modem Protection Switch 1 12 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 42: ...Operation SMS 758 Modem Protection Switch 3 4 MN SMS758 Rev 3 Figure 3 2 SMS 758 Display Map Sheet 1 of 2...
Страница 43: ...SMS 758 Modem Protection Switch Operation MN SMS758 Rev 3 3 5 Figure 3 2 SMS 758 Display Map Sheet 2 of 2...
Страница 60: ...Operation SMS 758 Modem Protection Switch 3 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 122: ...Maintenance SMS 758 Modem Protection Switch 5 10 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 144: ...Remote Control Operation SMS 758 Modem Protection Switch A 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 153: ...SMS 758 Modem Protection Switch Remote Control Operation MN SMS758 Rev 3 B 9 Where x 1 or 2 backup modem number...
Страница 168: ......
Страница 172: ...7 Downlink Option SMS 758 Modem Protection Switch C 4 MN SMS758 Rev 3 This page is intentionally left blank...