SMS-758 Modem Protection Switch
Theory of Operation
MN/SMS758 Rev. 3
4–21
4.6.3.1 Electrical Specifications
V.35
Circuit Supported
SD, SCT, SCTE, RD, SCR, DSR, DSR, RLSD
Switching Format
Modulator and demodulator signals individually
with dry contacts
Contact Arrangement
Mod Signals:
8 poles
Demod Signals:
8 poles
Amplitude (RD, SCR, SCT, SD, SCTE)
0.55V peak
±
20
%
differential into 100
Ω
Amplitude (CTS, DSR, RLSD)
10
±
5V into 5000
±
2000
Ω
Impedance (RD, SCR, SCT)
100
±
20
Ω
Impedance (SD, SCTE)
100
±
10
Ω
Impedance (RTS)
5000
±
2000
Ω
,
<
2500 pF
DC Offset (RD, SCR, SCT)
±
0.6V max., 1000
Ω
termination to ground
Polarity (SD, SCT, SCTE, RD, SCR)
True when B positive wrt A
False when A positive wrt B
Polarity (RTS, SCT, DSR, RLSD)
True when
<
-3V wrt GND
False when
>
+3V wrt GND
Phasing (SCTE, SCR)
False-to-true transition, nominally in center of data
bit
Symmetry (SCR, SCTE, SCT)
50
%
,
±
5
%
Frequency
±
100 PPM
Содержание SMS-758
Страница 2: ......
Страница 16: ...Table of Contents SMS 758 Modem Protection Switch xii MN SMS758 Rev 3 This page is intentionally left blank...
Страница 20: ...Introduction SMS 758 Modem Protection Switch 1 4 MN SMS758 Rev 3 Figure 1 2 System Block Diagram...
Страница 23: ...SMS 758 Modem Protection Switch Introduction MN SMS758 Rev 3 1 7 Figure 1 5 SMS 758 Block Diagram...
Страница 28: ...Introduction SMS 758 Modem Protection Switch 1 12 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 42: ...Operation SMS 758 Modem Protection Switch 3 4 MN SMS758 Rev 3 Figure 3 2 SMS 758 Display Map Sheet 1 of 2...
Страница 43: ...SMS 758 Modem Protection Switch Operation MN SMS758 Rev 3 3 5 Figure 3 2 SMS 758 Display Map Sheet 2 of 2...
Страница 60: ...Operation SMS 758 Modem Protection Switch 3 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 122: ...Maintenance SMS 758 Modem Protection Switch 5 10 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 144: ...Remote Control Operation SMS 758 Modem Protection Switch A 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 153: ...SMS 758 Modem Protection Switch Remote Control Operation MN SMS758 Rev 3 B 9 Where x 1 or 2 backup modem number...
Страница 168: ......
Страница 172: ...7 Downlink Option SMS 758 Modem Protection Switch C 4 MN SMS758 Rev 3 This page is intentionally left blank...