SMS-758 Modem Protection Switch
Maintenance
MN/SMS758 Rev. 3
5–3
5.2 Fault Isolation
The following tables list the procedures for clearing fault indications in the fault menu or
the remote interface (remote interface messages are listed in parentheses).
The tables list the fault messages on the left and the procedures on the right. To clear the
fault or to determine why the fault remains, be sure to perform the steps in the order
listed.
5.2.1 Modulator Operation
Faults
Procedures
BK-UP FAULT MOD X
(MOF_BU_OP_FLT_x)
If no M:N faults exist:
Verify that the switch is in AUTO mode.
Verify that a backup modulator is available to backup all of the
faulted prime modulators.
Verify that the data cable between the switch and the modem
is connected to the correct connectors.
If an M:N fault exists:
Check M:N faults for communication, configuration, and
compatibility faults. If there are faulted primes that are not
backed up, the modulator operation fault display will remain
ON.
Содержание SMS-758
Страница 2: ......
Страница 16: ...Table of Contents SMS 758 Modem Protection Switch xii MN SMS758 Rev 3 This page is intentionally left blank...
Страница 20: ...Introduction SMS 758 Modem Protection Switch 1 4 MN SMS758 Rev 3 Figure 1 2 System Block Diagram...
Страница 23: ...SMS 758 Modem Protection Switch Introduction MN SMS758 Rev 3 1 7 Figure 1 5 SMS 758 Block Diagram...
Страница 28: ...Introduction SMS 758 Modem Protection Switch 1 12 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 42: ...Operation SMS 758 Modem Protection Switch 3 4 MN SMS758 Rev 3 Figure 3 2 SMS 758 Display Map Sheet 1 of 2...
Страница 43: ...SMS 758 Modem Protection Switch Operation MN SMS758 Rev 3 3 5 Figure 3 2 SMS 758 Display Map Sheet 2 of 2...
Страница 60: ...Operation SMS 758 Modem Protection Switch 3 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 122: ...Maintenance SMS 758 Modem Protection Switch 5 10 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 144: ...Remote Control Operation SMS 758 Modem Protection Switch A 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 153: ...SMS 758 Modem Protection Switch Remote Control Operation MN SMS758 Rev 3 B 9 Where x 1 or 2 backup modem number...
Страница 168: ......
Страница 172: ...7 Downlink Option SMS 758 Modem Protection Switch C 4 MN SMS758 Rev 3 This page is intentionally left blank...