Remote Control Operation
SMS-758 Modem Protection Switch
B–22
MN/SMS758 Rev. 3
Character “x”: Missing parameters fault status character 5.
Bit 6 = 1 always.
Bit 5 = No address specified for prime modem #1 fault.
Bit 4 = No address specified for prime modem #2 fault.
Bit 3 = No address specified for prime modem #3 fault.
Bit 2 = No address specified for prime modem #4 fault.
Bit 1 = No address specified for prime modem #5 fault.
Bit 0 = No address specified for prime modem #6 fault.
Character “y”: Missing parameters fault status character 6.
Bit 6 = 1 always.
Bit 5 = No address specified for prime modem #7 fault.
Bit 4 = No address specified for prime modem #8 fault.
Bit 3 = No address specified for backup modem #1 fault.
Bit 2 = No address specified for backup modem #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Character “z”: Missing parameters fault status character 7.
Bit 6 = 1 always.
Bit 5 = No interface specified for prime modem #1 fault.
Bit 4 = No interface specified for prime modem #2 fault.
Bit 3 = No interface specified for prime modem #3 fault.
Bit 2 = No interface specified for prime modem #4 fault.
Bit 1 = No interface specified for prime modem #5 fault.
Bit 0 = No interface specified for prime modem #6 fault.
Character “aa”: Missing parameters fault status character 8.
Bit 6 = 1 always.
Bit 5 = No interface specified for prime modem #7 fault.
Bit 4 = No interface specified for prime modem #8 fault.
Bit 3 = No interface specified for backup modem #1 fault.
Bit 2 = No interface specified for backup modem #2 fault.
Bit 1 = Reserved.
Bit 0 = Reserved.
Character “ab”: Missing parameters fault status character 9.
Bit 6 = 1 always.
Bit 5 = No downlink specified for prime modem #1 fault.
Bit 4 = No downlink specified for prime modem #2 fault.
Bit 3 = No downlink specified for prime modem #3 fault.
Bit 2 = No downlink specified for prime modem #4 fault.
Bit 1 = No downlink specified for prime modem #5 fault.
Bit 0 = No downlink specified for prime modem #6 fault.
Character “ac”: Missing parameters fault status character 10.
Bit 6 = 1 always.
Bit 5 = No downlink specified for prime modem #7 fault.
Bit 4 = No downlink specified for prime modem #8 fault.
Bit 3 = Reserved.
Bit 2 = Reserved.
Bit 1 = Reserved.
Bit 0 = Reserved.
Содержание SMS-758
Страница 2: ......
Страница 16: ...Table of Contents SMS 758 Modem Protection Switch xii MN SMS758 Rev 3 This page is intentionally left blank...
Страница 20: ...Introduction SMS 758 Modem Protection Switch 1 4 MN SMS758 Rev 3 Figure 1 2 System Block Diagram...
Страница 23: ...SMS 758 Modem Protection Switch Introduction MN SMS758 Rev 3 1 7 Figure 1 5 SMS 758 Block Diagram...
Страница 28: ...Introduction SMS 758 Modem Protection Switch 1 12 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 42: ...Operation SMS 758 Modem Protection Switch 3 4 MN SMS758 Rev 3 Figure 3 2 SMS 758 Display Map Sheet 1 of 2...
Страница 43: ...SMS 758 Modem Protection Switch Operation MN SMS758 Rev 3 3 5 Figure 3 2 SMS 758 Display Map Sheet 2 of 2...
Страница 60: ...Operation SMS 758 Modem Protection Switch 3 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 122: ...Maintenance SMS 758 Modem Protection Switch 5 10 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 144: ...Remote Control Operation SMS 758 Modem Protection Switch A 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 153: ...SMS 758 Modem Protection Switch Remote Control Operation MN SMS758 Rev 3 B 9 Where x 1 or 2 backup modem number...
Страница 168: ......
Страница 172: ...7 Downlink Option SMS 758 Modem Protection Switch C 4 MN SMS758 Rev 3 This page is intentionally left blank...