SMS-758 Modem Protection Switch
Remote Control Operation
MN/SMS758 Rev. 3
A–13
A.3.5.5.3 Load Backup Modem Configuration
Command:
<add/LMC_Bx”cr”
Response:
>add/LMC_Bx”cr”
MOD_Bx_yyy”cr”
DMD_Bx_yyy”cr””lf”]
Where:
x = 1 or 2 (backup modem number).
yyy = OK or FLT.
A.3.5.6 Verify Modem Configuration(s)
These commands tell the switch to poll the specified modem(s) for configuration
information (via the modem remote control serial communications link). The received
configuration(s) are compared to the last loaded configuration(s).
A.3.5.6.1 Verify All Active Modems Configurations
This command verifies all the active modems configurations and returns status.
Command:
<add/VMC_ALL”cr”
Response:
>add/VMC_ALL”cr”
MOD_1_yyy”cr”
DMD_1_yyy”cr”
MOD_2_yyy”cr”
DMD_2_yyy”cr”
MOD_3_yyy”cr”
DMD_3_yyy”cr”
MOD_4_yyy”cr”
DMD_4_yyy”cr”
MOD_5_yyy”cr”
DMD_5_yyy”cr”
MOD_6_yyy”cr”
DMD_6_yyy”cr”
MOD_7_yyy”cr”
DMD_7_yyy”cr”
MOD_8_yyy”cr”
DMD_8_yyy”cr”
MOD_B1_yyy”cr”
DMD_B1_yyy”cr”
MOD_B2_yyy”cr”
DMD_B2_yyy”cr””lf”]
Where: yyy = OK or FLT.
Note: Response shown is for a system with all possible modulators and demodulators
active. Only active modulator and demodulator configurations will be verified and
reported.
Содержание SMS-758
Страница 2: ......
Страница 16: ...Table of Contents SMS 758 Modem Protection Switch xii MN SMS758 Rev 3 This page is intentionally left blank...
Страница 20: ...Introduction SMS 758 Modem Protection Switch 1 4 MN SMS758 Rev 3 Figure 1 2 System Block Diagram...
Страница 23: ...SMS 758 Modem Protection Switch Introduction MN SMS758 Rev 3 1 7 Figure 1 5 SMS 758 Block Diagram...
Страница 28: ...Introduction SMS 758 Modem Protection Switch 1 12 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 42: ...Operation SMS 758 Modem Protection Switch 3 4 MN SMS758 Rev 3 Figure 3 2 SMS 758 Display Map Sheet 1 of 2...
Страница 43: ...SMS 758 Modem Protection Switch Operation MN SMS758 Rev 3 3 5 Figure 3 2 SMS 758 Display Map Sheet 2 of 2...
Страница 60: ...Operation SMS 758 Modem Protection Switch 3 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 122: ...Maintenance SMS 758 Modem Protection Switch 5 10 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 144: ...Remote Control Operation SMS 758 Modem Protection Switch A 22 MN SMS758 Rev 3 This page is intentionally left blank...
Страница 153: ...SMS 758 Modem Protection Switch Remote Control Operation MN SMS758 Rev 3 B 9 Where x 1 or 2 backup modem number...
Страница 168: ......
Страница 172: ...7 Downlink Option SMS 758 Modem Protection Switch C 4 MN SMS758 Rev 3 This page is intentionally left blank...