![Comtech EF Data SDM-300L3 Скачать руководство пользователя страница 257](http://html1.mh-extra.com/html/comtech-ef-data/sdm-300l3/sdm-300l3_installation-and-operation-manual_2648475257.webp)
SDM-300L3 Satellite Modem
Revision 1
Fault Isolation
MN/SDM300L3.IOM
9–9
9.1.3.6 Backward
Alarms
Faults
Fault/Alarm
Possible Problem and Action
BW ALARM RX4
Receive backward alarm #4. The distant end of the link is sending
backward alarm #4. This indicates trouble at the distant end, which may
be a result of improper transmission at the near end of the link. The
modem will signal this event by setting the deferred maintenance alarm
(open collector). This alarm is a monitor function. The modem reports and
records the event, but takes no other action. Refer to Chapter 2 for the
backward alarm theory of operation. If the user does not wish to monitor
the backward alarm faults, the backward alarm inputs must be grounded at
the breakout panel. Refer to Chapter 2 for breakout panel pinouts.
BW ALARM RX3
Receive backward alarm #3. Refer to BW Alarm RX4 for details.
BW ALARM RX2
Receive backward alarm #2. Refer to BW Alarm RX4 for details.
BW ALARM RX1
Receive backward alarm #1. Refer to BW Alarm RX4 for details.
BW ALARM TX4
Transmit backward alarm #4. The modem is being instructed to send
backward alarm #4 to the distant end of the link. This alarm is controlled
by wiring the backward alarm inputs of the modem to the demod fault
relay and/or other fault outputs in the receive system (see IESS-308 for
clarification). The simplest implementation for single destination service is
to wire the demod fault relay between ground and the four backward
alarm inputs (see Chapter 3 for clarification). This sends all four backward
alarms in the event of any major (prompt) receive fault. This particular
alarm is transmitted, reported, and recorded, but the modem takes no other
action. In most cases, this will be sent due to some receive problem with
the modem, so a real fault will probably be occurring if backward alarms
are being sent. The transmit backward alarms are a symptom of trouble,
not a cause.
BW ALARM TX3
Transmit backward alarm #3. Refer to BW Alarm TX4 for details.
BW ALARM TX2
Transmit backward alarm #2. Refer to BW Alarm TX4 for details.
BW ALARM TX1
Transmit backward alarm #1. Refer to BW Alarm TX4 for details.
Содержание SDM-300L3
Страница 2: ......
Страница 36: ...SDM 300L3 Satellite Modem Revision 1 Introduction MN SDM300L3 IOM 1 16 This page is intentionally left blank...
Страница 200: ...SDM 300L3 Satellite Modem Revision 1 Front Panel Operation MN SDM300L3 IOM 4 132 This page is intentionally left blank...
Страница 258: ...SDM 300L3 Satellite Modem Revision 1 Fault Isolation MN SDM300L3 IOM 9 10 This page is intentionally left blank...
Страница 273: ...SDM 300L3 Satellite Modem Revision 1 Open Network Operations MN SDM300L3 IOM 10 15 Figure 10 4 E1 Framing Formats...
Страница 274: ...SDM 300L3 Satellite Modem Revision 1 Open Network Operations MN SDM300L3 IOM 10 16 Figure 10 5 T1 Framing Formats...
Страница 302: ...SDM 300L3 Satellite Modem Revision 1 G 703 MN SDM300L3 IOM 12 2 This page is intentionally left blank...
Страница 352: ...SDM 300L3 Satellite Modem Revision 1 BUC FSK Communications MN SDM300L3 IOM 15 4 This page is intentionally left blank...
Страница 408: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...