SDM-300L3 Satellite Modem
Revision 1
Fault Isolation
MN/SDM300L3.IOM
9–5
Test Note
Fault/Alarm Relay
Test Points Connector/Pins
1
TX FAULT
Pin 4 (NO), 5 (COM), 6 (NC) ****
2
RX FAULT
Pin 7 (NO), 8 (COM), 9 (NC) ****
3
COM EQ FAULT
Pin 1 (NO), 2 (COM), 3 (NC) ****
4
TX ALARM #2
Pin 4 (NO), 5 (COM), 6 (NC) +
5
RX ALARM #3
Pin 7 (NO), 8 (COM), 9 (NC) +
6
PRIMARY ALARM
Pin 43 (NO), 10 (COM), 27 (NC) +
7
SECONDARY ALARM
Pin 44 (NO), 11 (COM), 28 (NC) +
8
DEF MAINT ALARM
Pin 17 *****
* IDR
only.
** IBS
only.
*** D&I
only.
****
A connection between the common and N.C. contacts indicate fault.
*****
Signal is open collector high impedance if faulted.
+
A connection between the common and N.O. contacts indicate alarm.
Figure 9-1. SDM-300L3 Fault Tree (Continued)
Содержание SDM-300L3
Страница 2: ......
Страница 36: ...SDM 300L3 Satellite Modem Revision 1 Introduction MN SDM300L3 IOM 1 16 This page is intentionally left blank...
Страница 200: ...SDM 300L3 Satellite Modem Revision 1 Front Panel Operation MN SDM300L3 IOM 4 132 This page is intentionally left blank...
Страница 258: ...SDM 300L3 Satellite Modem Revision 1 Fault Isolation MN SDM300L3 IOM 9 10 This page is intentionally left blank...
Страница 273: ...SDM 300L3 Satellite Modem Revision 1 Open Network Operations MN SDM300L3 IOM 10 15 Figure 10 4 E1 Framing Formats...
Страница 274: ...SDM 300L3 Satellite Modem Revision 1 Open Network Operations MN SDM300L3 IOM 10 16 Figure 10 5 T1 Framing Formats...
Страница 302: ...SDM 300L3 Satellite Modem Revision 1 G 703 MN SDM300L3 IOM 12 2 This page is intentionally left blank...
Страница 352: ...SDM 300L3 Satellite Modem Revision 1 BUC FSK Communications MN SDM300L3 IOM 15 4 This page is intentionally left blank...
Страница 408: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...