SDM-300L3 Satellite Modem
Revision 1
Front Panel Operation
MN/SDM300L3.IOM
4–63
FUNCTION SELECT: MONITOR: BUFFER FILL
BUFFER FILL
50%
Displays the current plesiochronous buffer fill status percent. Range: 1 to 99%.
FUNCTION
SELECT:
MONITOR: FRAME ERRORS
(CONDITIONAL)
FRAME ERRORS
n.n E-e
2047 ERRORS
n.n E-e
IMPORTANT
Conditional:
This menu available only when the optional Overhead
Card is installed.
Displays the current framing pattern bit error rate or “No Data” (if carrier is not locked).
Monitors the currently selected READ_ERROR function.
Range: < mm.m E-e to > mm.m E-e.
Notes:
1.
Low limit is based on performance.
2.
High limit is based on the data/code rate.
Frame Errors
Measured when framed modes of operation are active.
2047 Errors
Measured when the RX 2047 PATTERN (under the Configuration: Interface
menu) is tuned On.
Содержание SDM-300L3
Страница 2: ......
Страница 36: ...SDM 300L3 Satellite Modem Revision 1 Introduction MN SDM300L3 IOM 1 16 This page is intentionally left blank...
Страница 200: ...SDM 300L3 Satellite Modem Revision 1 Front Panel Operation MN SDM300L3 IOM 4 132 This page is intentionally left blank...
Страница 258: ...SDM 300L3 Satellite Modem Revision 1 Fault Isolation MN SDM300L3 IOM 9 10 This page is intentionally left blank...
Страница 273: ...SDM 300L3 Satellite Modem Revision 1 Open Network Operations MN SDM300L3 IOM 10 15 Figure 10 4 E1 Framing Formats...
Страница 274: ...SDM 300L3 Satellite Modem Revision 1 Open Network Operations MN SDM300L3 IOM 10 16 Figure 10 5 T1 Framing Formats...
Страница 302: ...SDM 300L3 Satellite Modem Revision 1 G 703 MN SDM300L3 IOM 12 2 This page is intentionally left blank...
Страница 352: ...SDM 300L3 Satellite Modem Revision 1 BUC FSK Communications MN SDM300L3 IOM 15 4 This page is intentionally left blank...
Страница 408: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...