R-1170/1270 Redundancy Switch Controllers
Revision 0
Ethernet Interface Operation
5–8
MN-RC-1170/1270
5.4
HTTP (Web Server) Interface
A user-supplied web browser allows the full M&C of the RC-1170/1270 Redundancy Switch
Controller through its HTTP Interface. This embedded web application is designed for use with
Microsoft’s Internet Explorer Version 5.5 or higher. It is a non-secure web application.
5.4.1 Enable the HTTP Interface
Figure 5-4. Open Windows Command-line
Follow these steps to enable the HTTP Interface in the RC-1170/1270 Redundancy Switch
Controller using only a 100BaseTx remote interface (this assumes that you are running a
Microsoft Windows operating system):
See Figure 5-4 and do these steps:
1. Select
Start
, then
Run
, then type “
cmd
” to open the Windows Command-line window.
2. Type “
Telnet 192.168.1.4
” to start a Telnet session with the unit using the default
Management IP address.
and do these steps:
3. Enter the Telnet username and password (the default for both parameters is
comtech
):
4. The Local Remote Status (LRS) remote command sets or returns Local or Remote state
in the form x, where x=1, 2, or 3:
•
LRS=1 (Serial)
•
LRS=2 (Ethernet)
•
LRS=3 (Ethernet) (default value)
Use the
LRS=2
remote command to set the remote access parameter for Ethernet remote
control.