R-1170/1270 Redundancy Switch Controllers
Revision 0
Ethernet Interface Operation
5–7
MN-RC-1170/1270
To see the full response messages, you can use the Tera Term terminal emulation program
configured as a Telnet client. An example of the login process and remote control operation, when
using Tera Term as the interface, is shown in Figure 5-2.
Figure 5-2. Telnet Interface Example – Tera Term
5.3.1.1 Configure Tera Term for Telnet Remote Control Operation
Figure 5-3. Configure Tera Term
See Figure 5-3. Do these steps:
1. Make sure to define the Connect To Telnet connection properties correctly (new
connection prompt is displayed when Tera Term is started) (Figure 5-3):
a. Enter the RC-1170/1270 Redundancy Switch Controller’s Traffic/Management IP
Address as the “Host address” (e.g., 192.168.1.4).
b. Enter 23 as the “TCP port#”.
c. Select TCP/IP instead of Serial.
d. Click
[OK]
to save your settings.
2. For Terminal Setup (Setup
Terminal) (Figure 5-3, right):
a. Select the “CR+LF” option in the Receive dropdown box in the New-line section.
b. Select the “CR+LF” option in the Transmit dropdown box in the New-line
section.
c. Click
[OK]
to save your settings.