RC-1170/1270 Redundancy Switch Controllers
Revision 0
Front Panel Operation
3–7
MN-RC-1170/1270
3.2.1.1.3
Select: Config: Redundancy Menu
Table 3-8. Select: Config: Redundancy Menu
Menu Branch
Function
Redundancy
Mode
Select Auto or Manual.
If a unit fault is detected, an appropriate switchover will occur, and the system will fall
into manual mode.
If Manual mode is selected, the unit will not throw a switch in the event of a detected
fault.
3.2.1.1.4
Select: Config Mask Menu
Use the
◄ ►
arrow keys to select Unit 1/2/3 from this menu. Press ENTER to continue.
Select: Config: Mask: Unit
Table 3-9. Select: Config: Mask: Unit Menu
Menu Branch
Function
Current
Set to Alarm: If the unit current goes outside of the allowable window (window size and
window center calibrated point set by the user), an event is reported but does not cause a
switchover.
Set to Fault: An event is recorded, and the unit will switchover if in Auto Redundancy
mode.
Power Supply
Set to Alarm: If the unit bias voltage goes outside the allowable window (window size and
window center calibrated hard coded), an event is reported but does not cause a
switchover.
Set to Fault: An event is recorded, and the unit will switchover if in Auto Redundancy
mode.