PCB-4000A 1+1 Phase Combiner
Revision 2
Serial Remote Control
5–15
MN-PCB-4000A
Parameter
Type
Command
(Instruction
Code and
qualifier)
Command
Valid for
PCB or
SSPA
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Query Valid
for PCB or
SSPA
Response to
Query
(Target to
Controller)
Software
Revision
N/A
N/A
32 bytes
Query only.
Unit returns the firmware information for Boot, Image 1 (Bulk1)
and Image 2 (Bulk2) installed in the unit.
Example: SWR=Boot:1.1.1Bulk1:1.1.1Bulk2:1.1.1
N/A
SWR?
PCB
SWR=x...x
(see
description
of arguments)
Software
Image
IMG=
N/A
1 byte, value of
1 or 2
Command or Query.
Used to set the active software image for the next reboot in the
form x, where:
1=Boot from Bulk Image #1 for next reboot
2=Boot from Bulk Image #2 for next reboot
IMG=
IMG?
IMG*
IMG#
IMG?
PCB
IMG=x
(see
Description of
Arguments)
Force Reboot FRB=
PCB
None
Command only.
Force a hard reset of the unit in 5 seconds.
FRB=
FRB?
FRB*
FRB#
N/A
N/A
N/A
Terminal
Status
Change
N/A
N/A
1 byte, value of
0 or 1
Query only.
Unit returns the configuration change state since last time it’s
queried in the form x, where:
0=Unit configuration has not been changed since last query.
1=Unit configuration has been changed since last query.
N/A
TSC?
PCB
TSC=x
(see
Description of
Arguments)
SNMP Trap
Destination IP
Address 1
STA=
PCB
15 bytes,
Numerical
Command or Query.
Used to set the IP address of the first SNMP Trap destination
IP Address 1
Where traps will be sent in the form:
xxx.xxx.xxx.xxx is the IP addresss
Example:
<1/STA=010.006.030.001
When not configured, returns >0001/STA=0.0.0.0
STA=
STA!
STA=xxx.xxx.x
xx.xxx
(See
description of
arguments)
PCB
STA=xxx.xxx.x
xx.xxx
(See
description of
arguments)
SNMP Trap
Destination IP
Address 2
STB=
PCB
15 bytes,
Numerical
Command or Query.
Used to set the IP address of the first SNMP Trap destination
IP Address 2
Where traps will be sent, in the form:
xxx.xxx.xxx.xxx is the IP addresss
Example:
<1/STB=010.006.030.001
When not configured, returns >0001/STB=0.0.0.0
STB =
STB!
STB?
PCB
STB=xxx.xxx.x
xx.xxx
(See
description of