Parameter
Type
Command
(Instruction
Code and
qualifier)
Command
Valid for
PCB or
SSPA
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Query Valid
for PCB or
SSPA
Response to
Query
(Target to
Controller)
Summary
Fault Status
N/A
N/A
1 byte,
value of 0,1
Query only.
Used to Query the status of the Summary Fault Relay.
Example: SFS=0 where:
0 = OK
1 = FT
N/A
SFS?
SSPA
SFS=x
(see
Description of
Arguments for
details)
Remote
Address
SPA=
PCB
4 bytes,
numerical
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412
Default: 1
SPA=
SPA?
SPA?
PCB
SPA=x
(see
Description of
Arguments for
details)
Set RTC Time TIM=
ALL
6 bytes,
numerical
Command or Query.
A command in the form hhmmss, indicating the time from
midnight, where hh = hours, between 00 and 23; mm =
minutes, between 00 and 59, and ss = seconds, between 00
and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59
seconds past midnight.
TIM =
TIM?
TIM *
TIM?
ALL
TIM=xx
(see
Description of
Arguments for
details)
Retrieve
Number of
unread
Stored Alarms
N/A
N/A
2 bytes,
numerical
Query only.
Returns the number of Stored Events which remain unread, in
the form xx.
Example reply: TNA=18
N/A
TNA?
SSPA
TNA=xx
(see
Description of
Arguments for
details)
Initialize
Stored Alarms
Pointer
IAP=
ALL
None
Command only.
Resets internal pointer to allow LNA? Query to start at the
beginning of the stored alarms log.
IAP=
IAP?
IAP*
N/A
N/A
N/A
Remote State LRS=
PCB
1 byte, value of
1 or 3
Command or Query.
Used set the user’s Remote state in the form x, where:
1=Serial Remote (RS-232)
3=Ethernet Remote
Example: LRS=1 (selects Serial Remote)
LRS
LRS?
LRS*
LRS#
LRS?
PCB
LRS=x
(see
Description of
Arguments)
SNMP Read
Community
String
RCM=
PCB
Up to 20
characters, no
spaces
Command or Query.
Sets or returns the SNMP Read Community string.
Example: RCM=public
Notes: Empty string is not allowed.
RCM=
RCM?
RCM#
RCM?
PCB
RCM=x…x
(see
Description of
Arguments)