PCB-4000A 1+1 Phase Combiner
Revision 2
Serial Remote Control
5–11
MN-PCB-4000A
Parameter
Type
Command
(Instruction
Code and
qualifier)
Command
Valid for
PCB or
SSPA
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
qualifier)
Query Valid
for PCB or
SSPA
Response to
Query
(Target to
Controller)
Retrieve
Alarm Status
N/A
N/A
53 bytes
alphanumeric
Query only.
Used to Query the Alarm status of the unit.
Example: RAS=’cr’
P24VT=OK’cr’
P5VLT=OK’cr’
SSPA1=OK’cr’
SSPA2=OK’cr’
SSPA3=NA’cr’
SW1FT=OK’cr’
SW2FT=OK’’cr’’lf’
N/A
RAS?
ALL
(Check
SSPA
manual for
arguments
returned
from SSPA)
RAS=x….x
(see
Description of
Arguments for
details)
Retrieve
Configuration
Status
N/A
N/A
33 bytes
alphanumeric
Query only.
Used to Query the configuration status.
Example: RCS=’cr’
ATT=12.75’cr’
AMP=1’cr’
MUT=1’cr’
PCM=1,0’cr’
FLT=0,0,X’cr’’lf’ where:
ATT= attenuation in dB
AMP= RF power amplifier state, 0=OFF, 1=ON
MUT=RF mute state, 0=unmuted, 1=muted
PCM=Redundancy/Phase Combined mode,
0 = off
1 = 1:1 phase combine
2 = 1:2 phase combine (future)
3 = reserved
4 = reserved
FLT=X,Y,Z -> SSPAs fault state
X = SSPA#1 (1=faulted, 0=unfaulted)
Y = SSPA#2 (1=faulted, 0=unfaulted)
Z = reserved (X)
N/A
RCS?
SSPA
(per MBT
manual)
RCS=x….x
(see
Description of
Arguments for
details)