background image

- 15 -

10. Transmission distance inspection

With the help of the “

TEST

” button of the thermostats you can check whether 

the selected thermostat and the receiver unit are within the transmission 

distance of the radio-frequency connection. To perform the test, press the 

TEST

” button for approximately 2 seconds. Following this, the thermostat 

will send, alternating every 5 seconds, switch-on and switch-off control 

signals to the receiver for 2 minutes (the 

 

signal appears and disappears 

alternately on the display). When detecting the 

ON

 and 

OFF 

control signals, 

the red LED light associated with the thermostat on the receiver unit switches 

on and off, respectively. When the receiver unit fails to receive signals sent by 

the thermostat, then the receiver unit is outside the transmission distance of 

the wireless (radio-frequency) transmitter, thus they have to be placed closer to 

each other.

TECHNICAL DATA

Technical data of the thermostats (transmitters):

— temperature measurement range:

    

— adjustable temperature range: 

 

— temperature measurement accuracy:

 

— temperature calibration range:

 

 

— selectable switching sensitivity:

    

— storage temperature:

— battery voltage:

  

— power consumption:

— battery lifetime: 

— operating frequency:

— dimensions:

 

 

— weight:

— temperature sensor type:

5 to 35°C (in 0.1°C increments) 

5 to 35°C (in 0.5°C increments)

±0.5°C

±3°C (in 0.1°C increments)

±0.1°C; ±0.2°C; ±0.3°C

-10° t +

40

°C

2 x 1.5V 

ALKALINE

 batteries

(LR type

A

size

)

1.3mW

approx 1 ye

ar

 

868.35MHz

130 x 80 x 22mm (without holder)

112g

NTC 10kΩ ±1% at 25°C

Содержание Q8RF(TX)

Страница 1: ...COMPUTHERM Q8RF TX Multi zone programmable wireless radio frequency digital room thermostat Operating Instructions NEW design...

Страница 2: ...ure at the dates and times specified by you to reduce energy costs while maintaining comfort Separate temperature programs can be prepared for each day of the week For each day beside 1 fixed switchin...

Страница 3: ...9 8 C or below and switches it off at 20 2 C or above Please refer to Section 2 4 for the modification of the factory default switching sensitivity of 0 2 C The thermostat is equipped with a pump prot...

Страница 4: ...e thermostatic head may disturb the temperature control of the flat 2 PUTTING THE THERMOSTAT INTO OPERATION BASIC SETTINGS 2 1 Inserting batteries Pressing the lock on the upper side of the housing of...

Страница 5: ...between the heating and cooling mode There is a possibility to easily switch between the heating and cooling mode of the thermostat The output terminals of the receiver unit No 1 NO and No 2 COM are c...

Страница 6: ...deactivate this function using the large and buttons The notices and indicate activated and deactivated state respectively Finally confirm the setting by pressing the SET button if no buttons are pres...

Страница 7: ...ctivate more than one switch for each day Furthermore it is advised that a comfort temperature is used only those times when the room or building is in use since every 1 C decrease of temperature save...

Страница 8: ...s should be copied using the COPY button A separate program can be created for the heating and cooling mode and these programs are preserved when switching between the modes Therefore if the thermosta...

Страница 9: ...ich is indicated on the display of the device by flashing the temperature value to be set C by default Set the desired temperature using the large and buttons then press the PROG button e Then the sta...

Страница 10: ...the flashing abbreviation MON indicating Monday shows that conditions are ready for copying a program Select the day whose program you wish to copy to another day or other days using the large and but...

Страница 11: ...the new program as described in Sections 2 and 3 3 6 Program inspection First press the SET button to go to the main screen then press the PROG button At this point the abbreviation indicating the da...

Страница 12: ...program switch Set the required temperature using the large and buttons on the front panel of the device At this time the icon appears on the display indicating that the thermostat is operated with m...

Страница 13: ...anual control e g that is 3 days After this time has elapsed the icon disappears and the device resumes the program that has been set If you wish to return to the set program before the time set for t...

Страница 14: ...voltage appears on the display the batteries should be replaced see Section 2 1 The exact time should be set again after the batteries have been replaced but the device saves the program that has bee...

Страница 15: ...spectively When the receiver unit fails to receive signals sent by the thermostat then the receiver unit is outside the transmission distance of the wireless radio frequency transmitter thus they have...

Страница 16: ...Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C MONDAY MON SUNDAY SUN SATURDAY SAT FRIDAY FRI THURSDAY THU WEDNESDAY WED T...

Страница 17: ...t the temperature using the and buttons for a period of 1 to 9 hours set the temperature using the and buttons then press the DAY button and finally set the duration using the and buttons for a period...

Отзывы: