background image

factory value of the button. For example, if the current switch 

 

PROG

 

 

ensures 

a temperature of

 

°C,  it  can  be  modified  to  a  standard  temperature  that 

ensures  °C when needed by pressing the

 

 

button only once, without 

having to press the

 

 button several times in increments of 0.5°C. Following 

this, using the large

 

 

and

 

 

buttons, the temperature can be further 

modified in increments of 0.5°C, in accordance with current requirements.

The economy and comfort temperature values assigned to buttons

 

 

and

 

 

can be modified as follows:

• 

To set the economy temperature

, press the “

SET

” button and keep it 

depressed and press the

 

 

button, too. Following this, with the help 

of the

 

 

and

 

 

buttons, set the economy temperature selected 

by you. After the temperature has been set, press the “

SET

” button to 

save the modification (after approximately 15 seconds, it is automatically 

saved). Afterwards, the device goes back to the main screen.

• 

To set the comfort temperature

, press the “

SET

” button and keep it 

depressed and press the

 

 button, too. Following this, with the help of 

the

 

 

and

 

 

buttons, set the comfort temperature selected by you. 

After the temperature has been set, press the “

SET

” button to save the 

modification  (after approximately 15 seconds, it is automatically saved). 

Afterwards, the device goes back to the main screen.

4.1 Temperature modification until the next program switch

Set the required temperature using the large

 

 

and

 

 

buttons on the 

front panel of the device. At this time, the

 

 

icon appears on the display, 

indicating that the thermostat is operated with manual control. The device 

will control the boiler according to the set value until the time of the next 

switch specified in the program is reached.  
During this temporary modification, the segments indicating the time on the 

display alternately show the exact time 

(

TIME

and the time remaining 

(

TIME 

LEFT

in manual control (for example

  

, that is, 4 hours and 2 minutes). 

After this time has elapsed, the

 

 

icon disappears and the device resumes 

the program that has been set. If you wish to return to the set program 

before the time of the next switch is reached, please press the “

SET

” button.

4.2 Temperature modification for 1-9 hours (party program)

Set the required temperature using the large

 

 

and

 

 

buttons on the 

front panel of the device, and then press the “

DAY

” button. At this time, the 

 

 

icon appears on the display, along with number 1 in place of the switch 

number, which indicates the duration of modification in hours. Adjust this time 

to the desired length (between 

  

 and  ) using the large

 

 

and

 

 

buttons. 

The party program will start approximately 10 seconds after the adjustment. 

Following this, the device will keep the modified temperature for the given 

period of time. The adjusted temperature can be freely changed during the 

party program without exiting it. 

During  this  temporary  modification,  the  segments  indicating  the  time  on  the 

- 12 -

Содержание Q8RF(TX)

Страница 1: ...COMPUTHERM Q8RF TX Multi zone programmable wireless radio frequency digital room thermostat Operating Instructions NEW design...

Страница 2: ...ure at the dates and times specified by you to reduce energy costs while maintaining comfort Separate temperature programs can be prepared for each day of the week For each day beside 1 fixed switchin...

Страница 3: ...9 8 C or below and switches it off at 20 2 C or above Please refer to Section 2 4 for the modification of the factory default switching sensitivity of 0 2 C The thermostat is equipped with a pump prot...

Страница 4: ...e thermostatic head may disturb the temperature control of the flat 2 PUTTING THE THERMOSTAT INTO OPERATION BASIC SETTINGS 2 1 Inserting batteries Pressing the lock on the upper side of the housing of...

Страница 5: ...between the heating and cooling mode There is a possibility to easily switch between the heating and cooling mode of the thermostat The output terminals of the receiver unit No 1 NO and No 2 COM are c...

Страница 6: ...deactivate this function using the large and buttons The notices and indicate activated and deactivated state respectively Finally confirm the setting by pressing the SET button if no buttons are pres...

Страница 7: ...ctivate more than one switch for each day Furthermore it is advised that a comfort temperature is used only those times when the room or building is in use since every 1 C decrease of temperature save...

Страница 8: ...s should be copied using the COPY button A separate program can be created for the heating and cooling mode and these programs are preserved when switching between the modes Therefore if the thermosta...

Страница 9: ...ich is indicated on the display of the device by flashing the temperature value to be set C by default Set the desired temperature using the large and buttons then press the PROG button e Then the sta...

Страница 10: ...the flashing abbreviation MON indicating Monday shows that conditions are ready for copying a program Select the day whose program you wish to copy to another day or other days using the large and but...

Страница 11: ...the new program as described in Sections 2 and 3 3 6 Program inspection First press the SET button to go to the main screen then press the PROG button At this point the abbreviation indicating the da...

Страница 12: ...program switch Set the required temperature using the large and buttons on the front panel of the device At this time the icon appears on the display indicating that the thermostat is operated with m...

Страница 13: ...anual control e g that is 3 days After this time has elapsed the icon disappears and the device resumes the program that has been set If you wish to return to the set program before the time set for t...

Страница 14: ...voltage appears on the display the batteries should be replaced see Section 2 1 The exact time should be set again after the batteries have been replaced but the device saves the program that has bee...

Страница 15: ...spectively When the receiver unit fails to receive signals sent by the thermostat then the receiver unit is outside the transmission distance of the wireless radio frequency transmitter thus they have...

Страница 16: ...Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C Start time Temp C MONDAY MON SUNDAY SUN SATURDAY SAT FRIDAY FRI THURSDAY THU WEDNESDAY WED T...

Страница 17: ...t the temperature using the and buttons for a period of 1 to 9 hours set the temperature using the and buttons then press the DAY button and finally set the duration using the and buttons for a period...

Отзывы: