The portability of the thermostat offers the following advantages:

no need to lay a cable, which is especially advantageous when 

 

old buildings are being modernized

optimal location of the device can be selected during operation

 

it is also advantageous when you intend to locate the thermostat 

 

in different rooms in the course of the day (e.g. in the living 

room during the day but in the bedroom at night)

The  effective  range  of  the  transmitter  incorporated  in  the 

thermostat  is  approximately  50  m  in  open  terrain.  This  distance 
may  become  considerably  shorter  within  a  building,  especially 
when a metal structure or a reinforced concrete wall stands in the 
way of radio waves.

The switching sensitivity of the thermostat is ± 0.2°C (± 0.3°C). 

This means the difference between the adjusted temperature and 
the actual temperature measured during the switching process. For 
example, if the factory default setting is 20°C on the thermostat, 
then  the  device  switches  the  boiler  on  at  19.8°C  or  below,  and 
switches it off at 20.2°C or above.

This wireless (radio-frequency) thermostat can also be extended 

with the 

COMPUTHERM

 

Q1 RX

 socket if needed, with which the 

thermostat is able to control boilers or any other electrical devices 
operating on 230 V (50Hz; max. 10A)  (e.g. fan heaters, pumps, 
zone valves, etc.) according to the room temperature. (For more 
information please consult our website).

 - 3 -

Heating mode

Defrosting mode

Temperature 

display

Temperature 

measurement unit

Room temperature

Set temperature

The information shown on the liquid crystal display of the 

thermostat includes the following:

 

Содержание q3rf

Страница 1: ...COMPUTHERM Q3 RF wireless radio frequency digital room thermostat Operating Instructions...

Страница 2: ...w and above the adjusted temperature respectively and contributes to reduce energy costs while maintaining comfort The device consists of two units One of them is the portable control unit thermostat...

Страница 3: ...sensitivity of the thermostat is 0 2 C 0 3 C This means the difference between the adjusted temperature and the actual temperature measured during the switching process For example if the factory def...

Страница 4: ...maximum temperature in the room where the room thermostat is to be located otherwise the thermostatic head may disturb the temperature control of the flat 2 PUTTING THE THERMOSTAT INTO OPERATION BASI...

Страница 5: ...t of the Displayed Temperature The unit of measurement of the temperature shown on the LCD display can be selected and set by the central jumper With factory default settings the display shows the tem...

Страница 6: ...uble free wireless radio frequency connection both the thermostat and the receiver unit have their own safety codes After installing the receiver unit the two units should be synchronised by pressing...

Страница 7: ...rature is displayed 5 Operation of the Installed Thermostat After connecting commissioning and performing basic settings and setting the temperature the thermostat is ready for operation and controls...

Страница 8: ...is 1 year The icon alternately replacing the temperature value on the LCD display indicates low battery voltage Replace the batteries whenever the ddd icon indicating low battery voltage appears on t...

Страница 9: ...nt N while the phase conductor to point L We propose to interpose a switch so that the receiver unit can be de energized if required The receiver unit controls the boiler through a potential free alte...

Страница 10: ...the temperature of the room Following this the HEAT icon indicating that the heating is turned on should appear on the display of the thermostat within a few seconds At the same time the red LED ligh...

Страница 11: ...wo units are outside the transmission distance of the wireless radio frequency transmitter thus they have to be placed closer to each other 7 4 Manual control of the receiver unit Pressing the MANUAL...

Страница 12: ...ency 868 35 MHz power consumption 1 5 mW battery lifetime approx 1 year dimensions 112 x 75 x 45 mm weight 154 g temperature sensor type NTC 10 K 1 at 25 C Technical data of the receiver unit power co...

Отзывы: