background image

5.2 Defrosting Mode (left hand position of the switch)

In  the  left  hand  position  of  the  operating  mode  switch  the 

thermostat provides defrosting in the vicinity of the installation, and, 
in order to avoid the possibility of freezing, it switches the boiler or 
any other heating appliances connected to the thermostat on and 
off  below  and  above  +7.0°C,  respectively.  During  defrosting  the 
normally open contact pairs, i.e. No. 

1

 (NO) and No. 

(COM) of the 

relay of the receiver unit clamp shut and, as a consequence, the 
device connected to the receiver unit is switched on. The activated 
state  is  indicated  by  the  appearance  of  a              (snowflake)  icon 
on the LCD display. During defrosting the temperature adjustment 
buttons are inactive.

6. BATTERY REPLACEMENT

The average lifetime of the batteries is 1 year. The “     ” icon 

alternately  replacing  the  temperature  value  on  the  LCD  display 
indicates low battery voltage. Replace the batteries whenever the 

ddd

”  icon  indicating  low  battery  voltage  appears  on  the  display 

(see Section 3). After battery replacement, the desired temperature 
should be adjusted again, because during the battery replacement 
the thermostat is reset to factory default settings.

7. THE RECEIVER UNIT

7.1 Installation and connection of the receiver unit

The  receiver  unit  should  be  mounted  on  the  wall  in  a  place 

protected against moisture in the vicinity of the boiler. 

ATTENTION! 

Do  not  install  the  receiver  unit  under  the  housing 

of the boiler because it may shield radio signals and compromise 
wireless  (radio-frequency)  connection.  To  avoid  electric  shock, 
entrust a specialist with connecting the receiver unit to the boiler.

 

Unscrew the two screws at the bottom of the receiver unit without 

removing them. Following this, remove the front panel of the receiver 

 - 8 -

Содержание q3rf

Страница 1: ...COMPUTHERM Q3 RF wireless radio frequency digital room thermostat Operating Instructions...

Страница 2: ...w and above the adjusted temperature respectively and contributes to reduce energy costs while maintaining comfort The device consists of two units One of them is the portable control unit thermostat...

Страница 3: ...sensitivity of the thermostat is 0 2 C 0 3 C This means the difference between the adjusted temperature and the actual temperature measured during the switching process For example if the factory def...

Страница 4: ...maximum temperature in the room where the room thermostat is to be located otherwise the thermostatic head may disturb the temperature control of the flat 2 PUTTING THE THERMOSTAT INTO OPERATION BASI...

Страница 5: ...t of the Displayed Temperature The unit of measurement of the temperature shown on the LCD display can be selected and set by the central jumper With factory default settings the display shows the tem...

Страница 6: ...uble free wireless radio frequency connection both the thermostat and the receiver unit have their own safety codes After installing the receiver unit the two units should be synchronised by pressing...

Страница 7: ...rature is displayed 5 Operation of the Installed Thermostat After connecting commissioning and performing basic settings and setting the temperature the thermostat is ready for operation and controls...

Страница 8: ...is 1 year The icon alternately replacing the temperature value on the LCD display indicates low battery voltage Replace the batteries whenever the ddd icon indicating low battery voltage appears on t...

Страница 9: ...nt N while the phase conductor to point L We propose to interpose a switch so that the receiver unit can be de energized if required The receiver unit controls the boiler through a potential free alte...

Страница 10: ...the temperature of the room Following this the HEAT icon indicating that the heating is turned on should appear on the display of the thermostat within a few seconds At the same time the red LED ligh...

Страница 11: ...wo units are outside the transmission distance of the wireless radio frequency transmitter thus they have to be placed closer to each other 7 4 Manual control of the receiver unit Pressing the MANUAL...

Страница 12: ...ency 868 35 MHz power consumption 1 5 mW battery lifetime approx 1 year dimensions 112 x 75 x 45 mm weight 154 g temperature sensor type NTC 10 K 1 at 25 C Technical data of the receiver unit power co...

Отзывы: