background image

1. LOCATION OF THE DEVICE

The thermostat of the 

COMPUTHERM 

Q3 RF

 type device can 

be freely moved in your residence. It is reasonable to locate it in 
a room used regularly or for  many hours per day so that it is in 
the direction of natural ventilation in the room but protected from 
drought or extreme heat (e.g. direct sunlight, refrigerator, chimney, 
etc). Its optimal location is 1.5 m above floor level. It can be placed 
on its own stand or can be mounted on a wall. 

IMPORTANT  WARNING! 

If  the  radiator  valves  in  your  flat 

are  equipped  with  a  thermostatic  head,  replace  the  thermostatic 
head  of  the  radiator  valve  with  manual  control  knob  or  adjust  it 
to maximum temperature in the room where the room thermostat 
is to be located, otherwise the thermostatic head may disturb the 
temperature control of the flat.

2. PUTTING THE THERMOSTAT INTO OPERATION,    

    BASIC SETTINGS

To  put  the  thermostat  into  operation, 

detach the rear panel of the thermostat from 
the front panel by loosening the screws at the 
bottom of the cover as shown in the figure.

The  battery  compartment  is  in  the  inner  side  of  the  front 

panel of the housing. Insert 2 AA alkaline batteries (LR6 type) in 
accordance with the diagram in the battery compartment. After the 
batteries  have  been  inserted,  the  display  flashes  the  measured 
room temperature. (If this information fails to appear on the display, 
press the „

RESET

” button with a wooden or plastic stick. To press 

the  button,  do  not  use  any  electrically  conductive  materials  or 
graphite pencil).

 - 4 -

Содержание q3rf

Страница 1: ...COMPUTHERM Q3 RF wireless radio frequency digital room thermostat Operating Instructions...

Страница 2: ...w and above the adjusted temperature respectively and contributes to reduce energy costs while maintaining comfort The device consists of two units One of them is the portable control unit thermostat...

Страница 3: ...sensitivity of the thermostat is 0 2 C 0 3 C This means the difference between the adjusted temperature and the actual temperature measured during the switching process For example if the factory def...

Страница 4: ...maximum temperature in the room where the room thermostat is to be located otherwise the thermostatic head may disturb the temperature control of the flat 2 PUTTING THE THERMOSTAT INTO OPERATION BASI...

Страница 5: ...t of the Displayed Temperature The unit of measurement of the temperature shown on the LCD display can be selected and set by the central jumper With factory default settings the display shows the tem...

Страница 6: ...uble free wireless radio frequency connection both the thermostat and the receiver unit have their own safety codes After installing the receiver unit the two units should be synchronised by pressing...

Страница 7: ...rature is displayed 5 Operation of the Installed Thermostat After connecting commissioning and performing basic settings and setting the temperature the thermostat is ready for operation and controls...

Страница 8: ...is 1 year The icon alternately replacing the temperature value on the LCD display indicates low battery voltage Replace the batteries whenever the ddd icon indicating low battery voltage appears on t...

Страница 9: ...nt N while the phase conductor to point L We propose to interpose a switch so that the receiver unit can be de energized if required The receiver unit controls the boiler through a potential free alte...

Страница 10: ...the temperature of the room Following this the HEAT icon indicating that the heating is turned on should appear on the display of the thermostat within a few seconds At the same time the red LED ligh...

Страница 11: ...wo units are outside the transmission distance of the wireless radio frequency transmitter thus they have to be placed closer to each other 7 4 Manual control of the receiver unit Pressing the MANUAL...

Страница 12: ...ency 868 35 MHz power consumption 1 5 mW battery lifetime approx 1 year dimensions 112 x 75 x 45 mm weight 154 g temperature sensor type NTC 10 K 1 at 25 C Technical data of the receiver unit power co...