9-13
CAT-800 Long Timers
You can change any of the CAT-800 Long Timer settings by changing the time in the appropriate boxes
and clicking [SAVE SETTINGS] at the bottom of the page. When the CAT-800 is initialized, these timers
are automatically loaded with default values.
Port #1 Timeout Timer
This timer limits the time a signal can appear on the Port #1 receiver input. If this time limit is
exceeded the controller will turn off the transmitter. This timer is programmable between 60 and 1799
seconds. When the CAT-800 is initialized this timer defaults to 180 seconds.
Port #2 Timeout Timer
This timer limits the time a signal can appear on the Port #2 receiver input. If this time limit is
exceeded the controller will turn off the transmitter. When the CAT-800 is initialized this timer defaults
to 180 seconds.
Port #3 Timeout Time
This timer limits the time a signal can appear on the Port #3 receiver input. If this time limit is
exceeded the controller will turn off the transmitter. When the CAT-800 is initialized this timer defaults
to 180 seconds.
System ID Timer
This timer sets the time between ID transmissions. The ID occurs when a repeater user stops
transmitting. This timer is programmable between 60 and 1799 seconds. The timer default is 480
seconds.
Содержание CAT-800
Страница 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Страница 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Страница 88: ...11 2 DR 800 Digital Audio Player...
Страница 90: ...12 2 CAT 800 Sheet 1 of 4...
Страница 91: ...12 3 CAT 800 Sheet 2 of 4...
Страница 92: ...12 4 Sheet 3 of 4...
Страница 93: ...12 5 Sheet 4 of 4...
Страница 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...