2-5
Dipswitch Settings
An eight-position dipswitch configures various functions of the CAT-800.
Switch 1
This switch determines Port #1 COR input logic. Switch #1 should be ON if the Port #1
receiver's COR is an active low and OFF if COR is active high.
Switch 2
This switch determines Port #2 COR input logic. Switch #2 should be ON if the Port #2
receiver's COR is an active low and OFF if COR is active high.
Switch 3
This switch determines Port #3 COR input logic. Switch #3 should be ON if the Port #3
receiver's COR is an active low and OFF if COR is active high.
Switch 4
This switch determines the operation of Port #2. Switch #4 should be ON for full-duplex
transceiver operation and OFF for half-duplex transceiver operation.
Switch 5
This switch determines the operation of Port #3. Switch #5 should be ON for full-duplex
transceiver operation and OFF for half-duplex transceiver operation.
Switch 6
This switch places the CAT-800 in the cross band repeat mode. With transceivers on both Port
#1 and Port #2, enabled the link with the [A2] command. A signal received by the Port #1 receiver will
only key the Port #2 transmitter and a signal received by the Port #2 receiver will only key the Port #1
transmitter. With transceivers on both Port #1 and Port #3, enabled the link with the [A3] command. A
signal received by the Port #1 receiver will only key the Port #3 transmitter and a signal received by the
Port #3 receiver will only key the Port #1 transmitter. With transceivers on Port #1, Port #2 and Port
#3, enabled the link with the [A23] command. A signal received by the Port #1 receiver will key the
Port #2 and Port #3 transmitter and a signal received by the Port #2 or Port #3 receivers will key the
other transmitters. If dipswitch #6 is changed the power must be cycled for the change to take effect.
Switch 7
This switch is used to initialize the CAT-800. Set this switch to ON. Cycle the power OFF and
back ON. During power-up, the memory will be flushed and reloaded with default values. The voice will
say: "RESET SYSTEM OK." Set dipswitch #7 to the OFF position and recycle power.
Switch 8
This switch is used to program a new MASTER un-lock number. Set switch #8 to ON. The
voice will say: "ENTER CONTROL." After the seven-digit master unlock number is entered, set switch #8
to OFF.
Controller Security
Before placing the CAT-800 into operation five numbers should be changed. They are: the MASTER
Unlock number, the Secondary Unlock number and the Control Operator numbers for Port #1, Port #2
and Port #3. See page 5-1 to change the unlock numbers and page 5-14 to change the Control
Operator numbers.
Содержание CAT-800
Страница 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Страница 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Страница 88: ...11 2 DR 800 Digital Audio Player...
Страница 90: ...12 2 CAT 800 Sheet 1 of 4...
Страница 91: ...12 3 CAT 800 Sheet 2 of 4...
Страница 92: ...12 4 Sheet 3 of 4...
Страница 93: ...12 5 Sheet 4 of 4...
Страница 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...