5-17
Port #2 Inactivity Disconnect Timer [*605*]
This timer determines how long Port #2 remains inactive before event macro 38 executes. Control Zone
2 Channel 6 must be enabled. This timer is programmable between 60 and 1799 seconds. The timer
default is 600 seconds.
Port #3 Inactivity Disconnect Timer [*606*]
This timer determines how long Port #3 remains inactive before event macro 39 executes. Control Zone
3 Channel 6 must be enabled. This timer is programmable between 60 and 1799 seconds. The timer
default is 600 seconds.
Timed Message #1 Timer [*607*]
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 300 seconds.
Timed Message #2 Timer [*608*]
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 600 seconds.
Timed Message #3 Timer [*609*]
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 900 seconds.
Timed Message #4 Timer [*610]*]
This timer sets the timed message repeat period. This timer is programmable between 1.0 and 1799
seconds. The timer default is 1200 seconds.
PTT Off Message #1 Timer [*611*]
This timer sets the time between transmissions of the squelch tail message. The message occurs when
a repeater user stops transmitting. This timer is programmable between 1.0 and 1799 seconds. The
timer default is 1799 seconds.
PTT Off Message #2 Timer [*612*]
This timer sets the time between transmissions of the drop out message. The message occurs when a
repeater stops transmitting. This timer is programmable between 1.0 and 1799 seconds. The timer
default is 1799 seconds.
DTMF Programming Length Timer [*613*]
During the programming mode, this timer determines the maximum time the controller remains
unlocked. This timer is programmable between 60 and 1799 seconds. When initialize, this timer will
default to 600 second.
DTMF Access Sleep Timer [*614*]
This timer determines the time required for the repeater to be at rest before the DTMF access code is
required to activate the repeater. This timer is programmable between 60 and 1799 seconds. The timer
default is 60 seconds.
COR Drop to Courtesy Beep Timer [*620*]
This timer determines the time between loss of COR and generation of the courtesy beep. This timer is
programmable between 0.1 and 9.9 seconds. When initialize, this timer defaults to 1 second. Example:
To program the timer for 2.5 seconds, key-up and enter [*620*25].
Courtesy Beep to PTT Drop Timer [*621*]
This timer determines the time between the generation of the courtesy beep and the time the repeater
transmitter turns off. This timer is programmable between 0.1 and 9.9 seconds. The timer default is 4
seconds.
Содержание CAT-800
Страница 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Страница 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Страница 88: ...11 2 DR 800 Digital Audio Player...
Страница 90: ...12 2 CAT 800 Sheet 1 of 4...
Страница 91: ...12 3 CAT 800 Sheet 2 of 4...
Страница 92: ...12 4 Sheet 3 of 4...
Страница 93: ...12 5 Sheet 4 of 4...
Страница 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...