5-16
Voice Demonstration Control Number [*509*]
This programming command selects the number that must be entered to PLAY one of the voice
messages. This number must precede the voice message number. Example: To program a Voice
Demonstration Control Number of 700, key-up and send [*509*700]. Un-key and the voice will say:
"CONTROL OK."
Play Digital Audio WAV Track Control Number [*510*]
This programming command selects the number that must be entered to PLAY one of the digital audio
tracks. This number must precede the two-digit track number. Example: To program a Play Audio
Track Control Number of 725, key-up and send [*510*725]. Un-key and the voice will say: "CONTROL
OK."
Reserved [*511*]
This programming command is reserved for future use.
Secondary Unlock Number [*512*]
This programming command selects the secondary unlock number used to place the CAT-800 in the
programming mode. This number is not restricted to a seven-digit number. The default number is
[7654321].
Read Control And Prefix Numbers [*501 - *512]
Use this programming command to read the Port #1 control operator code. Example: Key-up and enter
[*501], un-key and the voice will say: "CODE FIVE ZERO ONE IS ONE ZERO ZERO."
Timer Memory
This memory area is reserved for storage of [19] timers. These timers are user programmable. When
the CAT-800 is initialized, these timers are automatically loaded with default values.
Port #1 Timeout Timer [*601*]
This timer limits the time a signal can appear on the Port #1 receiver input. If this time limit is
exceeded the controller will turn off the transmitter. This timer is programmable between 60 and 1799
seconds. Example: To program the Port #1 timer for 3 minutes, key-up and enter [*601*180]. Un-key
and the voice will say: "CONTROL OK." When the CAT-800 is initialized this timer defaults to 180
seconds.
Port #2 Timeout Timer [*602*]
This timer limits the time a signal can appear on the Port #2 receiver input. If this time limit is
exceeded the controller will turn off the transmitter. When the CAT-800 is initialized this timer defaults
to 180 seconds.
Port #3 Timeout Timer [*603*]
This timer limits the time a signal can appear on the Port #3 receiver input. If this time limit is
exceeded the controller will turn off the transmitter. When the CAT-800 is initialized this timer defaults
to 180 seconds.
System ID Timer [*604*]
This timer sets the time between transmissions of the Port #1 ID. The ID occurs when a repeater user
stops transmitting. This timer is programmable between 60 and 1799 seconds. The timer default is 480
seconds.
Programming Command Time (180 Seconds)
(Timeout Timer Port #1)
*601 * 180
Содержание CAT-800
Страница 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Страница 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Страница 88: ...11 2 DR 800 Digital Audio Player...
Страница 90: ...12 2 CAT 800 Sheet 1 of 4...
Страница 91: ...12 3 CAT 800 Sheet 2 of 4...
Страница 92: ...12 4 Sheet 3 of 4...
Страница 93: ...12 5 Sheet 4 of 4...
Страница 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...