![Computer Automation Technology CAT-800 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/computer-automation-technology/cat-800/cat-800_manual_2647939019.webp)
3-4
Read Firmware Version
To read the current firmware version of the CAT-800, key-up and enter the control operator prefix code
followed by [100*8]. Un-key and the CAT-
800’s voice will say: “VERSION TWO POINT ZERO ZERO”.
The default control operator code for Port #1 is [100]. EXAMPLE: Key-up and enter [100*8]. Use the
default control operator code [200] for Port #2 and [300] for Port #3.
Perform Remote Control Reset
To perform a remote control reset of the CAT-800, key-up and enter the control operator prefix code
followed by [100*9]. Un-key and the CAT-
800’s voice will say: “EXPECT MICRO RESET”. The default
control operator code for Port #1 is [100]. EXAMPLE: Key-up and enter [100*9]. Use the default
control operator code [200] for Port #2 and [300] for Port #3. This procedure is identical to cycling the
DC power to the CAT-
800 and will not effect it’s programming.
NOTE: Since the microprocessor is running in several different loops it may be possible to reset the
controller remotely. However for the reset to work the microprocessor must be able to recognize the
[100*9] command. If the microprocessor has stopped executing its program it is not likely it will respond
to your reset command. You will need to cycle DC power on the controller.
Содержание CAT-800
Страница 42: ...5 13 3634 SET PORT 3 CTCSS LOGIC COR OR CTCSS ACTIVE LO...
Страница 87: ...11 1 Chapter 11 Drawings CAT 800 Repeater Controller Board...
Страница 88: ...11 2 DR 800 Digital Audio Player...
Страница 90: ...12 2 CAT 800 Sheet 1 of 4...
Страница 91: ...12 3 CAT 800 Sheet 2 of 4...
Страница 92: ...12 4 Sheet 3 of 4...
Страница 93: ...12 5 Sheet 4 of 4...
Страница 94: ...12 6 DR 800 Digital Audio WAV Player Sheet 1 of 1...