To change the graph zone that a sensor is displayed, simply right click on the sensor name and choose
“Properties.” In the “Channel Properties” window you will see a text box next to each sensor’s name
that marks the specific zone the graph will be displayed in. In general you want sensors with a similar
range to be in the same zone that way you can see the specific graph in full range (putting a 2000 psi
sensor in the same graph zone as a 30 psi sensor will make the 30 psi look like a straight line regardless
of change because the range is 0 – 2000 instead of 0-30.)
To customize views, simply modify the view as you like and choose “View” and “Save View as
Custom View” and choose the specific number you would like associate the view to.
S
HORTCUT
K
EYS
I
=
Zoom In
O
=
Zoom Out
W
=
View Whole Run
Z
=
Set Zero Time
Z
ONES
When viewing your runs on the
D
ATA
M
AXX
viewer software, each sensor is displayed in a specific zone.
To get the most out of your data, it is recommended to place channels that have similar ranges in the
same zone. Ex. A 30 psi sensor will look like a flat line in the same zone as a 2000 psi sensor because
their ranges are so drastically different. The zones can be changed in the channel properties screen.
Default Zone Settings:
1. Switches
2. Main RPM (engine, drive, input)
3. Derived RPM (converter slippage, gear ratio)
4. Low Temperature
5. Exhaust Gas Temperature
6. Accelerometer
7. Pressure
T
RUNCATING
L
OG
FILES
If you find that you have extra data at the end of the run that is not needed, you can truncate (delete) the
unwanted data. To do so, open the log file, place the cursor at the point you want to delete information
and choose View, then “Truncate Log file after Cursor.”