Alarm (warning, compressor continues to run)
ALARM: OIL FILT
Maintenance interval exceeded
ALARM: SEPARATOR
Maintenance interval exceeded
ALARM: AIR FIL
Maintenance interval exceeded
ALARM: OIL CHANG
Maintenance interval exceeded
ALARM: GREASE M1
Maintenance interval exceeded
ALARM: BELTS
Maintenance interval exceeded
ALARM: T --.-
.°C
T Oil/air mixture temperature at the compressor outlet high.
STOP:T LOW --.-
.°C
The ambient temperature is too low. The compressor start is disabled.
Alarms for maintenance are triggered at the set time before maintenance. The alarm message is
displayed intermittently and repeatedly in the case of an overrun maintenance interval.
Error messages (compressor stops or does not start)
ERROR STOP
STOP: M1 OVERLD
--.-. A
Current consumption main motor too high
STOP: M1 SHORT
--.-. A
Short circuit on the main motor
STOP: FAN OVERLD
--.-. A
Current consumption fan motor too high
STOP: FAN SHORT
--.-. A
Short circuit on the fan motor
STOP: PH. MISS
Phase error main motor
STOP: PHASE UNBL
Phasedisbalance at the main motor
STOP: P HIGH
--.- bar
Permissible operating pressure exceeded
STOP: FAN PHASE
Phase error fan motor
STOP: FAN UNBL
Phasedisbalance at the fan motor
STOP: EMERG STOP
Compressor does not start. EMERGENCY STOP button pressed
The controller saves the last 5 errors.
Restarting operation without eliminating the cause of the fault
isnot permitted!