132 (cluster member 2). The device unit number is an alias for the
worldwide name for the storage unit.
•
The reachability part of the display provides the followng:
–
The worldwide name for the storage unit that is to be accessed
–
The new device name for the KGPSA
–
Whether access is available through a port
–
The HSG80 port (N_Port) that will be used to access the storage
unit
–
The
connected
column indicates the HSG80 controller ports
that will be used to access the storage units. The HSG80
controllers are in multiple-bus failover, so only one controller
is active.
Example 6–3: Using the wwidmgr quickset Command to Set Device Unit
Number
P00>>>
wwidmgr -quickset -udid 133
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d60-0009-8080-0434-002e
via adapter:
via fc nport:
connected:
dga133.1001.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d64
No
dga133.1002.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d62
Yes
dga133.1003.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d63
No
dga133.1004.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d61
Yes
dgb133.1001.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d64
No
dgb133.1002.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d62
Yes
dgb133.1003.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d63
No
dgb133.1004.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d61
Yes
P00>>>
wwidmgr -quickset -udid 131
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d60-0009-8080-0434-002e
via adapter:
via fc nport:
connected:
dga133.1001.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d64
No
dga133.1002.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d62
Yes
dga133.1003.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d63
No
dga133.1004.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d61
Yes
dgb133.1001.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d64
No
dgb133.1002.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d62
Yes
dgb133.1003.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d63
No
dgb133.1004.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d61
Yes
6000-1fe1-0000-0d60-0009-8080-0434-002f
via adapter:
via fc nport:
connected:
dga131.1001.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d64
No
dga131.1002.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d62
Yes
dga131.1003.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d63
No
dga131.1004.0.1.0
pga0.0.0.1.0
5000-1fe1-0000-0d61
Yes
dgb131.1001.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d64
No
dgb131.1002.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d62
Yes
dgb131.1003.0.2.0
pgb0.0.0.2.0
5000-1fe1-0000-0d63
No
Using Fibre Channel Storage 6–43
Содержание TruCluster Server AA-RHGWB-TE
Страница 16: ......
Страница 22: ...cluster Bold text indicates a term that is defined in the glossary xxii About This Manual...
Страница 52: ......
Страница 78: ......
Страница 110: ......
Страница 174: ......
Страница 250: ......
Страница 282: ......
Страница 302: ......
Страница 304: ......
Страница 315: ...Y Y cables connecting devices with 9 6 supported 2 10 Index 11...
Страница 316: ......
Страница 318: ......