2-3
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Server Management Comments:
File Name: D-ch2.doc Last Saved On: 4/23/97 11:14 AM
Level II Temperature,
Immediate Shutdown
When temperatures exceed the factory preset level II temperature threshold,
the hardware tracking of the system thermal environment executes an
immediate system shutdown. This shutdown decreases the potential for heat-
related damage to the system components.
Storage Subsystem Thermal Tracking
If your server has an external SCSI storage subsystem, the storage chassis
thermal environment can be monitored to alert the Compaq Insight Manager
console when the subsystem’s temperature exceeds the factory preset
temperature threshold.
Network Fault Prevention Tracking
Your server tracks six fault prevention parameters of Ethernet and Token Ring
network interfaces, such as excessive collisions or frames transmitted after
single or multiple collisions. This prevents impending network interface
problems.
Memory Fault Prevention Tracking
Your server tracks the operation of the ECC memory subsystem, looking for
any correctable memory errors. This allows you to schedule maintenance to
either avert or recover from impending ECC memory failures.