8-51
Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages
continued
Message
Description
Recommended Action
Drive (bay) X is
undergoing drive
recovery
This drive is being rebuilt
from the corresponding
mirror or parity data.
Normal operations should occur.
Drive (bay) X was
inadvertently replaced
The physical drive was
incorrectly replaced after
another drive failed.
Replace the drive that was incorrectly replaced
and replace the original drive that failed. Do not
run the System Configuration Utility and try to
reconfigure - data will be lost.
SCSI port X, drive ID Y
firmware needs
upgrading
Drive’s firmware may
cause problems and
should be upgraded.
Run Options ROMPaq to upgrade the drive’s
firmware to a later revision.
Set configuration
command issued
The configuration of the
array controller has been
updated. The array
accelerator board may
remain disabled until it is
reinitialized.
Run the System Configuration Utility to
reinitialize the array accelerator board.
Soft Firmware Upgrade
required
DAAD has determined that
your controller is running
firmware that has been
soft upgraded by the
Compaq Upgrade Utility.
However, the firmware
running is not present on
all drives. This could be
caused by the addition of
new drives in the system.
Run the Compaq Upgrade Utility to place the
latest firmware on all drives.
continued