Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
POST Error Messages
continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1789-Drive Not
Responding, Physical
Drive
Check cables or
replace physical drive
X
.
Select F1 to continue
- drive array will
remain disabled.
Select F2 to fail
drive(s) that are not
responding -
Interim Recovery
Mode will be enabled
if configured for fault
tolerance.
None
Cable or hard drive
failure.
1. Check the cable
connections.
2. If cables are
connected, replace
the drive.
3. If you do not want
to replace the
drives now, press
F2.
1790-Disk 0 Error
None
Hard drive error or wrong
drive type
Run the System
Configuration Utility.
1790-Disk 0
Configuration Error
None
Hard drive error or wrong
drive type
Run the System
Configuration Utility
and Diagnostics.
1791-Disk 1 Error
None
Hard drive error or wrong
drive type.
Run the System
Configuration Utility
and Diagnostics and
correct.