Compaq ProLiant 800 Server Reference Guide
Writer: Project: Diagnostics Tools Comments:
File Name: J-ch8.doc Last Saved On: 4/24/97 10:38 AM
DAAD Diagnostic Messages
continued
Message
Description
Recommended Action
FYI: Drive (bay) X is non-
Compaq supplied
The installed drive was not
supplied by Compaq.
If problems exist with this drive, replace it with
a Compaq drive.
Identify controller data
did not match with
NVRAM
The identify controller data
from the array controller
did not match with the
information stored in
nonvolatile RAM. This
could occur if new,
previously configured
drives have been placed in
a system that has also
been previously
configured. It could also
occur if the firmware on
the controller has been
upgraded and the System
Configuration Utility was
not run.
Check the identify controller data under the
Inspect Utility. If the firmware version field is
the only thing different between the controller
and nonvolatile RAM data, this is not a problem.
Otherwise run the System Configuration Utility.
Identify logical drive data
did not match with
NVRAM
The identify unit data from
the array controller did not
match with the information
stored in nonvolatile RAM.
This could occur if new,
previously configured
drives have been placed in
a system that has also
been previously
configured.
Run the System Configuration Utility to
configure the controller and nonvolatile RAM.
continued