INS_CWGE10FX2TX8MSPOE 02/19/21 PAGE 106
INSTALLATION AND OPERATION MANUAL
CWGE10FX2TX8MSPOE
TECH SUPPORT: 1.888.678.9427
Web Configuration
Parameter
Description
State
Enables/Disables the PD Alive Check.
Port
Selects a port or a range of ports which you want to configure.
State
Enables/Disables the PD Alive Check for the specific port(s).
IP Address
Specifies the Host IP address which connects to the port.
Interval
The interval to send the packet probes to check if the host is still alive.
Retry Time
The retry times when no response from the host for the keep-a-live probe packet.
Action
The action to the Power Device when the system detects that the Power Device
cannot respond the keep-a-live probe packet. The options have Reboot / Alarm /
All /None.
Power Off Time
When PD has been rebooted, the PoE port restored power after the Power Off
Time time.
Start Up Time
The Switch waits the Start Up Time to do PoE Auto Checking when the PD is
rebooting.
Apply
Click Apply to take effect the settings.
Refresh
Click Refresh to begin reset these values without saving.