background image

INSTALLATION AND OPERATION MANUAL 

CWGE10FX2TX8MSPOE

COMMERCIAL GRADE MANAGED LAYER2 ETHERNET SWITCH  

WITH (8) 10/100/1000TX POE+ PORTS + (2) 1000FX SFP PORTS

The ComNet CWGE10FX2TX8MSPOE has eight 10/100/1000Base-TX RJ-45 ports 
and two 100/1000Base-FX SFP ports. All SFP ports utilize ComNet SFP* modules 
for fiber, connector type and distance. The IEEE802.3-compliant unit offers multiple 
Ethernet redundancy protocols (RSTP & STP) which protect your applications from 
network interruptions or temporary malfunctions by redirecting transmission within 
the network. The CWGE10FX2TX8MSPOE implements ACLs to restrict access to your 
sensitive network resources by filtering specific packets based on TCP/UDP ports, 
source and destination IP addresses or particular network devices.

Содержание CWGE10FX2TX8MSPOE

Страница 1: ...Net SFP modules for fiber connector type and distance The IEEE802 3 compliant unit offers multiple Ethernet redundancy protocols RSTP STP which protect your applications from network interruptions or temporary malfunctions by redirecting transmission within the network The CWGE10FX2TX8MSPOE implements ACLs to restrict access to your sensitive network resources by filtering specific packets based o...

Страница 2: ...Software Features 6 Hardware Features 7 Hardware Description 8 SFP modules 9 Installation 11 Connect Power 11 LED Indicators 12 Management options 13 Management via console port 13 Management by Telnet 14 How to enter the CLI 14 CLI command concept 15 Management via Internet Browser Interface 16 System Information 16 CLI Configuration 16 Basic Settings 18 General Settings 18 Jumbo Frame 21 MAC Man...

Страница 3: ...81 Link Aggregation 82 Link Layer Discovery Protocol LLDP 90 Loop Detection 94 Power over Ethernet PoE 98 Web Configuration 103 Spanning Tree Protocols STP RSTP 109 Monitor 120 Hardware Information 120 Port Statistics 121 Port Utilization 122 RMON Statistics 124 SFP Information 125 Web Configuration 125 Traffic Monitor 126 Security 129 ACL 129 Management 135 SNMP 135 Mail Alarm 140 Maintenance 144...

Страница 4: ...next generation of video solutions for the CCTV defense and homeland security markets At the core of ComNet s solutions are a variety of high end video servers and the ComNet IVS software which provide the industry with a standard platform for analytics and security management systems enabling leading performance compact and cost effective solutions ComNet s products are available in commercial an...

Страница 5: ...cols RSTP STP which protect your applications from network interruptions or temporary malfunctions by redirecting transmission within the network The CWGE10FX2TX8MSPOE implements ACLs to restrict access to your sensitive network resources by filtering specific packets based on TCP UDP ports source and destination IP addresses or particular network devices The eight electrical ports support the 10 ...

Страница 6: ...2 v3 Email Alarm IEEE 802 1ab LLDP Network Management Telnet Web based GUI Auto Logout Timer SNMP v1 v2c SNMP Trap RMON 1 2 3 and 9 Private MIB Local Remote Syslog support SFP DDMI support Status display and event report Firmware upgrade by TFTP HTTP FTP Configuration Backup Restore Traffic Management QoS 256 Active VLAN Support MAC based VLAN Port isolation 802 1p Priority Queues per port Traffic...

Страница 7: ...1 888 678 9427 Hardware Features Operating temperature 0 C to 50 C Storage temperature 40 C to 70 C Operating humidity 10 to 80 RH no condensing Storage humidity 5 to 90 RH no condensing Cooling Fan Fanless Case Material Metal housing Dimension WxHxD 12 99 8 03 1 67 in 33 20 4 4 2 cm Weight 5 2 lb 2 4 kg ...

Страница 8: ...ors functioning under Ethernet Fast Ethernet Gigabit Ethernet standards 10 100 1000Base T Ports The 10 100 1000Base T ports support network speeds of 10Mbps 100Mbps or 1000Mbps and can operate in half and full duplex transfer modes These ports also offer automatic MDI MDI X crossover detection that gives true plug n play capability just plug the network cables into the ports and the ports will adj...

Страница 9: ...contamination 2 Position the SFP transceiver with the handle on top see the following figure 3 Locate the triangular marking in the slot and align it with the bottom of the transceiver 4 Insert the SFP transceiver into the slot until it clicks into place 5 Make sure the module is seated correctly before sliding the module into the slot A click sounds when it is locked in place Figure 2 7 Installin...

Страница 10: ...The fiber port is now setup Removing SFP Modules To disconnect an LC connector use the following guidelines 1 Press down and hold the locking clips on the upper side of the optic cable 2 Pull the optic cable out to release it from the transceiver Figure 2 9 Removing a Fiber Optic Cable to a Transceiver 3 Hold the handle on the transceiver and pull the transceiver out of the slot Figure 2 10 Removi...

Страница 11: ... treatment Connect a grounding wire and lug to the grounding point on the switch rear panel and then to rack ground Caution The earth connection must not be removed unless all supply connections have been disconnected The Switch uses an AC power supply 100 240VAC 50 60 Hz 2 1A The Switch s power supply automatically self adjusts to the local power source and may be powered on without having any or...

Страница 12: ... Illuminated System ready to use Blinking Power on self test Off Power off or test fail PoE Maximum Amber Illuminated PoE devices draw maximum power ALARM Red Illuminated Alarm for over threshold of system temperature or voltage loop detection Off Switch is in normal condition Copper ports 1 8 10 100 1000Mbps 1000 Green Illuminated 1000Mbps Off 10 100Mbps LNK ACT Green Illuminated Ethernet link up...

Страница 13: ... all of the methods described The administration console and web browser interfaces are embedded in the Switch software and can be used immediately after setup Management via console port Access the Switch via a terminal emulator such as Hyper Terminal attached to the console port The console port is set at the factory with the following default COM port properties Configure your own terminal to m...

Страница 14: ... 192 168 10 1 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 Management VLAN 1 Default Username admin Default Password admin 3 Make sure your computer IP address is in the same subnet unless you are accessing the Switch through one or more routers How to enter the CLI Press Enter key to enter the login command prompt when below message is displayed on the screen Please press Enter to activate t...

Страница 15: ...minal eth0 Its command prompt is CWGE10FX2TX8MSPOE config if It means these commands can be executed in this command prompt In Configure code executing command interface eth0 enter the eth0 interface node CWGE10FX2TX8MSPOE config interface eth0 CWGE10FX2TX8MSPOE config if interface Its command prompt is CWGE10FX2TX8MSPOE config if It means these commands can be executed in this command prompt In C...

Страница 16: ... through CLI interface Default User name admin Password admin System Information The System Information window appears each time you log into the program Alternatively this window can be accessed by clicking System Status System Information CLI Configuration Node Command Description enable show hostname This command displays the system s network name enable show interface eth0 This command display...

Страница 17: ...dress of the Switch Subnet Mask This field indicates the subnet mask of the Switch Default Gateway This field indicates the default gateway of the Switch MAC Address This field displays the MAC Media Access Control address of the Switch Serial Number The serial number assigned by manufacture for identification of the unit Management VLAN This field displays the VLAN ID that is used for the Switch ...

Страница 18: ...anagement VLAN the management VLAN should be created first and the management VLAN should have at least one member port Host Name The hostname is same as the SNMP system name Its length is up to 64 characters The first 16 characters of the hostname will be configured as the CLI prompt Default Settings The default Hostname is CWGE10FX2TX8MSPOE The default DHCP client is disabled The default Static ...

Страница 19: ... c parameter allow user to specific the packet count The default count is 4 The s parameter allow user to specific the packet size Valid range 0 1047 bytes configure reboot This command reboots the system configure hostname STRINGS This command sets the system s network name configure interface eth0 This command enters the eth0 interface node to configure the system IP configure configure terminal...

Страница 20: ...cters for the name of your Switch The hostname should be the combination of the digit or the alphabet or hyphens or underscores _ Management VLAN Enter a VLAN ID used for Switch management purposes IPv4 Settings DHCP Client Select Enable to allow the Switch to automatically get an IP address from a DHCP server Click Renew to have the Switch reget an IP address from the DHCP server Select Disable i...

Страница 21: ...e the packet will be dropped The available values are 10240 1522 1536 1552 9216 Default Setting The default jumbo frame is 10240 bytes 0CLI Configuration Node Command Description enable show jumboframe This command displays the current jumbo frame settings configure jumboframe 10240 1522 1536 1552 9010 9216 This command configures the maximum number of bytes of frame size for all ports Example The...

Страница 22: ...ods of time is known as the Simple Network Time Protocol SNTP NTP provides Coordinated Universal Time UTC No information about time zones or daylight saving time is transmitted this information is outside its scope and must be obtained separately UDP Port 123 Daylight saving is a period from late spring to early fall when many countries set their clocks ahead of normal local time by one hour to gi...

Страница 23: ...ll re get the time from NTP server every 24 hours 6 If the time zone and time NTP server have been changed the Switch will repeat the query process 7 No default SNTP server Default Settings Current Time Time 0 3 51 UTC Date 1970 1 1 Time Server Configuration Time Zone 00 00 IP Address 0 0 0 0 DayLight Saving Time Configuration State disabled Start Date None End Date None ...

Страница 24: ...ond third fourth last Sunday Monday Tuesday Wednesday Thursday Friday Saturday MONTH HOUR This command sets the start time of the Daylight Saving Time configure time daylight saving time end date first second third fourth last Sunday Monday Tuesday Wednesday Thursday Friday Saturday MONTH HOUR This command sets the end time of the Daylight Saving Time configure time ntp server disable enable This ...

Страница 25: ...and time manually New Time Enter the new date in year month and day format and time in hour minute and second format The new date and time then appear in the Current Date and Current Time fields after you click Apply Enable Network Time Protocol Select this option to use Network Time Protocol NTP for the time service NTP Server Select a pre designated time server or type the IP address of your tim...

Страница 26: ... would select Last Sunday 3 March and the last field depends on your time zone In Germany for instance you would select 2 00 because Germany s time zone is one hour ahead of GMT or UTC GMT 1 End Date Configure the day and time when Daylight Saving Time ends if you enabled Daylight Saving Time The time field uses the 24 hour format Examples Daylight Saving Time ends in the United States on the last...

Страница 27: ...ommand Description enable show interface eth0 The command displays the all of the interface eth0 configurations eth0 show The command displays the all of the interface eth0 configurations eth0 management host A B C D The command adds a management host address eth0 management subnet host A B C D M The command adds a management host address with a subnet mask Which allows user to specify a range of ...

Страница 28: ...bit which allows to configure a range of hosts If you do not specify value the system will give 32 for the host automatically Apply Click this button to take effect the settings Refresh Click this button to begin configuring this screen afresh Management Host List No This field displays a sequential number for each management host Management Host This field displays the management host and number ...

Страница 29: ...he Switch s ports When a device which may belong to a VLAN group sends a packet which is forwarded to a port on the Switch the MAC address of the device is shown on the Switch s MAC Table It also shows whether the MAC address is dynamic learned by the Switch or static manually entered The Switch uses the MAC Table to determine how to forward frames See the following figure 1 The Switch examines a ...

Страница 30: ...ss table mac MACADDR This command displays information of a specific MAC enable show mac address table port PORT_ID This command displays the current unicast address entries learnt by the specific port configure mac address table static MACADDR vlan 1 4094 port PORT_ID This command configures a static unicast entry configure no mac address table static MACADDR vlan 1 4094 This command removes a st...

Страница 31: ...lid format is hh hh hh hh hh hh VLAN ID Enter the VLAN ID to apply to the computer or device Port Enter the port number to which the computer or device is connected Apply Click Apply to take effect the settings Refresh Click this to update the information in the MAC table Static MAC Table MAC Address This field displays the MAC address of a manually entered MAC address entry VLAN ID This field dis...

Страница 32: ...y was entered manually Static or whether it was learned by the Switch Dynamic VLAN ID This field displays the VLAN ID of the MAC address entry Port This field displays the port number the MAC address entry is associated It displays CPU if it is the entry for the Switch itself The CPU means that it is the Switch s MAC Total Counts This field displays the total entries in the MAC table Age Time Sett...

Страница 33: ... Users can monitor the selected ports Source Ports for egress and or ingress packets Source Mode Ingress The received packets will be copied to the monitor port Egress The transmitted packets will be copied to the monitor port Both The received and transmitted packets will be copied to the monitor port Note 1 The monitor port cannot be a trunk member port 2 The monitor port cannot be ingress or eg...

Страница 34: ...nation port PORT_ID This command specifies the monitor port for the port mirroring configure mirror source ports PORT_LIST mode both ingress egress This command adds a port or a range of ports as the source ports of the port mirroring configure no mirror source ports PORT_LIST This command removes a port or a range of ports from the source ports of the port mirroring Example CWGE10FX2TX8MSPOE conf...

Страница 35: ...if you want to make some settings the same for all ports Use this field first to set the common settings and then make adjustments on a port by port basis Source Port This field displays the number of a port Mirror Mode Select Ingress Egress or Both to only copy the ingress incoming egress outgoing or both incoming and outgoing traffic from the specified source ports to the monitor port Select Dis...

Страница 36: ...mmunications device and returned looped back to it as a way to determine whether the device is working right or as a way to pin down a failing node in a network One type of loopback test is performed using a special plug called a wrap plug that is inserted in a port on a communications device The effect of a wrap plug is to cause transmitted output data to be returned as received input data simula...

Страница 37: ...feature the Switch determines the connection speed by detecting the signal on the cable and using half duplex mode When the Switch s auto negotiation is turned off a port uses the pre configured speed and duplex mode when making a connection thus requiring you to make sure that the settings of the peer port are the same in order to connect Flow Control A concentration of traffic on a port decrease...

Страница 38: ...ific port interface no shutdown This command enables the specific port interface description STRING This command configures a description for the specific port interface no description This command configures the default port description interface cable test start This command starts to diagnostics the Ethernet cable interface show cable test result This command displays the test result of the Eth...

Страница 39: ...POE configure terminal CWGE10FX2TX8MSPOE show int 1 0 2 Port Index 2 Description gigabitethernet1 0 2 Speed Nway Status Normally Uptime 0 days 0 0 0 Medium mode Copper Flow Control Off Default VLAN ID 1 Join VLAN 1 Operating Status No Connection Default QoS priority 0 Acceptable frame type all Administrative Status Enable EEE Status Disable ...

Страница 40: ...o deactivate the port Speed Duplex Select the speed and duplex mode of the port The choices are Auto 10 Mbps Full 10 Mbps Full Nway 10 Mbps Half 100 Mbps Full 100 Mbps Full Nway 100 Mbps Half 1000 Mbps Full 1000 Mbps Full Nway Notice For compatibility concerns we support three new speeds as below 10 Mbps Full Nway The Nway is enabled but its ability has 10M only 100 Mbps Full Nway The Nway is enab...

Страница 41: ... port number State This field displays whether the port is enabled or disabled Speed Duplex This field displays the speed either 10M 100M or 1000M and the duplex mode Full or Half Flow Control This field displays whether the port s flow control is On or Off Link Status This field displays the link status of the port If the port is up it displays the port s speed duplex and flow control setting Oth...

Страница 42: ...erate on a best effort delivery basis which means that all traffic has equal priority and an equal chance of being delivered in a timely manner When congestion occurs all traffic has an equal chance of being dropped When you configure the QoS feature you can select specific network traffic prioritize it according to its relative importance and use congestion management and congestion avoidance tec...

Страница 43: ...ets based on their Differentiated Services Code Points DSCPs Note Advanced QoS methods only affect the internal priority queue mapping for the Switch The Switch does not modify the IEEE 802 1p value for the egress frames You can choose one of these ways to alter the way incoming packets are prioritized or you can choose not to use any QoS enhancement setting on the Switch 802 1p Priority When usin...

Страница 44: ...anagement Priority Levels PCP Priority Code Point PCP Network Priority Traffic Characteristics 1 0 lowest Background 0 1 Best Effort 2 2 Excellent Effort 3 3 Critical Applications 4 4 Video 100 ms latency 5 5 Video 10 ms latency 6 6 Internetwork Control 7 7 highest Network Control DiffServ DSCP Differentiated Services or DiffServ is a computer networking architecture that specifies a simple scalab...

Страница 45: ... traffic as more important than other traffic generally by accepting only traffic above a certain precedence at time of high load The major choice is a three way tradeoff between low delay high reliability and high throughput Bits 0 2 Precedence Bit 3 0 Normal Delay 1 Low Delay Bits 4 0 Normal Throughput 1 High Throughput Bits 5 0 Normal Reliability 1 High Reliability Bit 6 7 Reserved for Future U...

Страница 46: ...dware priority queues in order beginning with the highest priority queue 3 to the lowest priority queue 0 Each hardware queue will transmit all of the packets in its buffer before permitting the next lower priority to transmit its packets When the lowest hardware priority queue has finished transmitting all of its packets the highest hardware priority queue will begin transmitting any packets it m...

Страница 47: ...ble bandwidth across the different traffic queues and returns to queues that have not yet emptied Default Settings Qos mode High First SPQ The mappings of the Priority to Queue are PRIO 0 COSQ 2 PRIO 1 COSQ 0 PRIO 2 COSQ 1 PRIO 3 COSQ 3 PRIO 4 COSQ 4 PRIO 5 COSQ 5 PRIO 6 COSQ 6 PRIO 7 COSQ 7 The DiffServ is disabled on the switch DSCP Priority DSCP Priority DSCP Priority DSCP Priority 00 0 01 0 02...

Страница 48: ... transmit its packets configure qos mode wrr queue weights 1 127 1 127 1 127 1 127 1 127 1 127 1 127 1 127 This command configures the QoS scheduling mode to Weighted Round Robin configure qos mode wfr queue weights 1 127 1 127 1 127 1 127 1 127 1 127 1 127 1 127 This command configures the QoS scheduling mode to Weighted fair scheduling interface default priority 0 7 This command allows the user ...

Страница 49: ... indicates packet priority and is added to the priority tag field of incoming packets The values range from 0 lowest priority to 7 highest priority Port This field displays the number of a port 802 1p Priority Select a priority for packets received by the port Only packets without a 802 1p priority tagged will be applied the priority you set here Apply Click Apply to take effect the settings Refre...

Страница 50: ...rameter Description Mode Tag Over DSCP or DSCP Over Tag Tag Over DSCP means the 802 1p tag has higher priority than DSCP Priority This field displays each priority level The values range from 0 lowest priority to 7 highest priority Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh ...

Страница 51: ...Default Click this button to reset the priority to queue mappings to the defaults Priority This field displays each priority level The values range from 0 lowest priority to 7 highest priority Queue ID Select the number of a queue for packets with the priority level Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh ...

Страница 52: ...WRR or Weighted Fair Queuing WFQ is selected Queue ID This field indicates which Queue 0 to 7 you are configuring Queue 0 has the lowest priority and Queue 7 the highest priority Weight Value You can only configure the queue weights when Weighted Round Robin WRR or Weighted Fair Queuing WFQ is selected Bandwidth is divided across the different traffic queues according to their weights Apply Click ...

Страница 53: ... per second on the ports When the maximum number of allowable broadcast multicast and unknown unicast packets is reached per second the subsequent packets are discarded Enable this feature to reduce broadcast multicast and unknown unicast packets in your network Storm Control unit pps Default Settings Broadcast Storm Control 300 pps Multicast Storm Control None DLF Storm Control 300 pps CLI Config...

Страница 54: ...t Broadcast to specify a limit for the amount of broadcast packets received per second Multicast to specify a limit for the amount of multicast packets received per second DLF to specify a limit for the amount of DLF packets received per second Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Bandwidth Limitation The rate limitation is use...

Страница 55: ...ets and set the limitation configure no bandwidth limit egress ports PORTLISTS This command disables the bandwidth limit for outgoing packets configure bandwidth limit ingress RATE_ LIMIT ports PORTLISTS This command enables the bandwidth limit for incoming packets and set the limitation configure no bandwidth limit ingress ports PORTLISTS This command disables the bandwidth limit for incoming pac...

Страница 56: ... Web Configuration Parameter Description Port Selects a port that you want to configure Ingress Configures the rate limitation for the ingress packets Egress Configures the rate limitation for the egress packets Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh ...

Страница 57: ...s You can configure the Switch to automatically learn multicast group membership of any VLANs The Switch then performs IGMP snooping on the first VLANs that send IGMP packets This is referred to as auto mode Alternatively you can specify the VLANs that IGMP snooping should be performed on This is referred to as fixed mode In fixed mode the Switch does not learn multicast group membership of any VL...

Страница 58: ...h attached network for which this router is the Querier to solicit membership information On startup a router SHOULD send Startup Query Count General Queries spaced closely together Startup Query Interval in order to quickly and reliably determine membership information A General Query is addressed to the all systems multicast group 224 0 0 1 has a Group Address field of 0 and has a Max Response T...

Страница 59: ...Node Command Description enable show igmp snooping This command displays the current IGMP snooping configurations enable show igmp snooping querier This command displays the current IGMP Queriers and the querier configurations enable show igmp counters port vlan This command displays the current IGMP snooping counters per port or per vlan enable show multicast This command displays the multicast g...

Страница 60: ...igabitethernet1 0 PORTLISTS This command enters the interface configure node if range igmp immediate leave This command enables the IGMP Snooping immediate leave function for the specific ports if range no igmp immediate leave This command disables the IGMP Snooping immediate leave function for the specific ports if range igmp snooping group limit VALUE This command configures the maximum groups f...

Страница 61: ...Ns Select Delete and enter VLANs on which to have the Switch not perform IGMP snooping Unknown Multicast Packets Specify the action to perform when the Switch receives an unknown multicast frame Select Drop to discard the frame s Select Flooding to send the frame s to all ports Apply Click Apply to configure the settings Refresh Click this to reset the fields to the last setting IGMP Snooping Stat...

Страница 62: ...e Switch does not use the port as an IGMP query port In this case the Switch does not keep a record of an IGMP router being connected to this port and the Switch does not forward IGMP join or leave packets to this port Immediate Leave Select individual ports on which to enable immediate leave Group Limit Configures the maximum group for the port or a range of ports Apply Click Apply to apply the s...

Страница 63: ...ress are mapped into the 23 bits of available Ethernet address space This means that there is ambiguity in delivering packets If two hosts on the same subnet each subscribe to a different multicast group whose address differs only in the first 5 bits Ethernet packets for both multicast groups will be delivered to both hosts requiring the network software in the hosts to discard the unrequired pack...

Страница 64: ...ignated routers on a network segment 224 0 0 9 The RIP version 2 group address Used to send routing information using the RIP protocol to all RIP v2 aware routers on a network segment 224 0 0 10 EIGRP group address Used to send EIGRP routing information to all EIGRP routers on a network segment 224 0 0 13 PIM Version 2 Protocol Independent Multicast 224 0 0 18 Virtual Router Redundancy Protocol 22...

Страница 65: ... vlan configure mac address table multicast MACADDR vlan 1 4094 ports PORTLIST This command configures a static multicast entry configure no mac address table multicast MACADDR This command removes a static multicast entry from the address table Web Configuration Parameter Description VLAN ID Configures the VLAN that you want to configure MAC Address Configures the multicast MAC which will not be ...

Страница 66: ... to talk to each other you must define the egress port for both ports CPU refers to the Switch management port By default it forms a VLAN with all Ethernet ports If it does not form a VLAN with a particular port then the Switch cannot be managed from that port Example If you want to allow port 1 and port 3 to talk to each other you must configure as below CWGE10FX2TX8MSPOE config interface 1 0 1 C...

Страница 67: ...d displays the current port isolation configurations V indicates the port s packets can be sent to that port indicates the port s packets cannot be sent to that port interface port isolation ports PORTLISTS This command configures a port or a range of ports to egress traffic from the specific port interface no port isolation This command configures all ports to egress traffic from the specific por...

Страница 68: ...acket leaves Selecting a port as an outgoing port means it will communicate with the port currently being configured Select All Deselect All Click Select All to mark all ports as egress ports and permit traffic Click Deselect All to unmark all ports and isolate them Deselecting all ports means the port being configured cannot communicate with any other port Apply Click Apply to configure the setti...

Страница 69: ... bytes of TCI Tag Control Information starts after the source address field of the Ethernet frame The CFI Canonical Format Indicator is a single bit flag always set to zero for Ethernet switches If a frame received at an Ethernet port has a CFI set to 1 then that frame should not be forwarded as it is to an untagged port The remaining twelve bits define the VLAN ID giving a possible maximum number...

Страница 70: ... The device that is attached to the port likely has no understanding that a VLAN exists The device simply knows that it is a member of a subnet and that the device should be able to talk to all other members of the subnet by simply sending information to the cable segment The switch is responsible for identifying that the information came from a specific VLAN and for ensuring that the information ...

Страница 71: ...rom the vlan vlan tagged PORTLISTS This command assigns ports for tagged member of the VLAN group The ports should be one some of the permanent members of the vlan vlan no tagged PORTLISTS This command removes all tagged member from the vlan vlan untagged PORTLISTS This command assigns ports for untagged member of the VLAN group The ports should be one some of the permanent members of the vlan vla...

Страница 72: ...ISTS This command assigns ports for tagged member of the VLAN group The ports should be one some of the permanent members of the vlans vlan range no tagged PORTLISTS This command removes all tagged member from the vlans vlan range untagged PORTLISTS This command assigns ports for untagged member of the VLAN group The ports should be one some of the permanent members of the vlans vlan range no unta...

Страница 73: ...nt the Switch to assign to the VLAN as members You can designate multiple port numbers individually by using a comma and by range with a hyphen Apply Click Apply to save your changes back to the Switch Refresh Click Refresh to begin configuring this screen afresh VLAN List VLAN ID This field displays the index number of the VLAN entry Click the number to modify the VLAN VLAN Name This field displa...

Страница 74: ...ort will tag all outgoing frames transmitted with the VLAN ID Select All Click Select All to mark all member ports as tag ports Deselect All Click Deselect All to mark all member ports as untag ports Apply Click Apply to save your changes back to the Switch Refresh Click Refresh to begin configuring this screen afresh Tag Status VLAN ID This field displays the VLAN ID Tag Ports This field displays...

Страница 75: ...p down list box to accept all untagged or tagged frames on this port This is the default setting Select VLAN Tagged Only to accept only tagged frames on this port All untagged frames will be dropped Select VLAN Untagged Only to accept only untagged frames on this port All tagged frames will be dropped Apply Click Apply to save your changes back to the Switch Refresh Click Refresh to begin configur...

Страница 76: ...2 member ports Note The 802 1Q port base VLAN should be created first CLI Configuration Node Command Description enable show mac vlan This command displays the all of the mac vlan configurations configure mac vlan STRINGS vlan 1 4094 priority 0 7 This command creates a mac vlan entry with the leading three or more bytes of mac address and the VLAN and the priority configure no mac vlan entry STRIN...

Страница 77: ...2TX8MSPOE TECH SUPPORT 1 888 678 9427 Web Configuration Parameter Description MAC Address Configures the leading three or more bytes of the MAC address VLAN Configures the VLAN Priority Configures the 802 1Q priority Action Click the Delete button to delete the protocol VLAN profile ...

Страница 78: ... network whereas the secondary one is attached to a wireless network When dual homing feature is enabling by default through primary connection the device will get connect to Internet at the same time the secondary connection will be shutdown If the port or all the ports of primary connection are link down then the device will replace its primary connection by the secondary one to connect with the...

Страница 79: ...command sets the dual homing primary channel for a group The channel can be a single port or a trunk group configure no dual homing group 1 3 primary channel This command resets the dual homing primary channel for a group configure dual homing group 1 3 secondary channel port trunk VALUE This command sets the dual homing secondary channel for a group The channel can be a single port or a trunk gro...

Страница 80: ...oming for a group Primary channel Configures Resets the primary channel for a group The channel can be single port or a trunk group Secondary channel Configures Resets the secondary channel for a group The channel can be single port or a trunk group Dual Homing Status Group ID The group number Group State The state of the group Primary Channel The primary channel configurations and current link st...

Страница 81: ...vices EEE provides the protocol needed to transition into and out of LPI mode in a way that is transparent to upper layer protocols and applications Note This feature is for Ethernet copper ports only Default Settings All ports EEE states are disabled CLI Configuration Node Command Description enable show interface IFNAME This command displays the current port configurations interface power effici...

Страница 82: ...ne logical higher capacity link You may want to trunk ports if for example it is cheaper to use multiple lower speed links than to under utilize a high speed but more costly single port link However the more ports you aggregate then the fewer available ports you have A trunk group is one logical link containing multiple ports The Switch supports both static and dynamic link aggregation Note In a p...

Страница 83: ...egation GROUP_ID disable enable The command disables enables the trunk on the specific trunk group configure link aggregation GROUP_ID interface PORTLISTS The command adds ports to a specific trunk group configure no link aggregation GROUP_ID interface PORTLISTS The commands delete ports from a specific trunk group Example CWGE10FX2TX8MSPOE configure terminal CWGE10FX2TX8MSPOE config link aggregat...

Страница 84: ...e this static trunk group Member Ports Select the ports to be added to the static trunk group Apply Click Apply to configure the settings Refresh Click this to reset the fields to the last setting Trunk Group Status Group ID This field displays the group ID to identify a trunk group that is one logical link containing multiple ports State This field displays if the trunk group is enabled or disabl...

Страница 85: ...ACP before you connect the Ethernet switch to avoid causing network topology loops System Priority The switch with the lowest system priority and lowest port number if system priority is the same becomes the LACP server The LACP server controls the operation of LACP setup Enter a number to set the priority of an active port using Link Aggregation Control Protocol LACP The smaller the number the hi...

Страница 86: ...isable enable This command disables enables the LACP on the specific trunk group configure clear lacp counters PORT_ID This command clears the LACP statistics for the specific port or all ports configure lacp system priority 1 65535 This command configures the system priority for the LACP Note The default value is 32768 configure no lacp system priority This command configures the default for the ...

Страница 87: ...INS_CWGE10FX2TX8MSPOE 02 19 21 PAGE 87 INSTALLATION AND OPERATION MANUAL CWGE10FX2TX8MSPOE TECH SUPPORT 1 888 678 9427 Web Configuration LACP Settings ...

Страница 88: ...number to set the priority of an active port using Link Aggregation Control Protocol LACP The smaller the number the higher the priority level Group LACP Select a trunk group ID and then select whether to Enable or Disable Group Link Aggregation Control Protocol for that trunk group Port Priority Select a port or a range of ports to configure its their LACP priority Apply Click Apply to configure ...

Страница 89: ...0 65535 Default 32768 System ID The neighbor Switch s system ID Port The direct connected port Id of the neighbor Switch Age The available time period of the neighbor Switch LACP information Port State The direct connected port s state of the neighbor Switch Port Priority The direct connected port s priority of the neighbor Switch Oper Key The Oper key of the neighbor Switch Internal Information P...

Страница 90: ...anagement of those capabilities and the identification of the station s point of attachment to the IEEE 802 LAN required by those management entity or entities The information distributed via this protocol is stored by its recipients in a standard Management Information Base MIB making it possible for the information to be accessed by a Network Management System NMS using a management protocol suc...

Страница 91: ...e TTL of the Switch s message TTL tx hold tx interval interface lldp agent disable enable rx only tx only This command configures the LLDP agent function disable Disable the LLDP on the specific port enable Transmit and Receive the LLDP packet on the specific port tx only Transmit the LLDP packet on the specific port only rx only Receive the LLDP packet on the specific port configure interface ran...

Страница 92: ...on the Switch Tx Interval Configures the interval to transmit the LLDP packets Tx Hold Configures the tx hold time which determines the TTL of the Switch s message TTL tx hold tx interval Time To Live The hold time for the Switch s information Port The port range which you want to configure State Enables disables the LLDP on these ports LLDP Status Port The Port ID State The LLDP state for the spe...

Страница 93: ... display the port s neighbor information Local Port The local port ID Remote Port ID The connected port ID Chassis ID The neighbor s chassis ID System Name The neighbor s system name System Description The neighbor s system description System Capabilities The neighbor s capability Management Address The neighbor s management address Time To Live The hold time for the neighbor s information ...

Страница 94: ...P The loop detection function sends probe packets periodically to detect if the port connect to a network in loop state The Switch shuts down a port if the Switch detects that probe packets loop back to the same port of the Switch Loop Recovery When the loop detection is enabled the Switch will send one probe packets every two seconds and then listen this packet If it receives the packet at the sa...

Страница 95: ...gurations configure loop detection disable enable This command disables enables the loop detection on the switch configure loop detection address MACADDR This command configures the destination MAC for the loop detection special packets configure no loop detection address This command configures the destination MAC to default 00 0b 04 AA AA AB interface loop detection disable enable This command d...

Страница 96: ...he Switch MAC Address Enter the destination MAC address the probe packets will be sent to If the port receives these same packets the port will be shut down Port Select a port on which to configure loop guard protection State Select Enable to use the loop guard feature on the Switch Loop Recovery Select Enable to reactivate the port automatically after the designated recovery time has passed Recov...

Страница 97: ...iption Loop Guard Status Port This field displays a port number State This field displays if the loop guard feature is enabled Status This field displays if the port is blocked Loop Recovery This field displays if the loop recovery feature is enabled Recovery Time min This field displays the recovery time for the loop recovery feature ...

Страница 98: ...n standard schemes had been used prior to PoE standardization to provide power over Ethernet cabling Some are still in active use PSE Power sourcing equipment PSE is a device such as a switch that provides sources power on the Ethernet cable PD A powered device PD is a device such as an access point or a switch that supports PoE Power over Ethernet so that it can receive power from another device ...

Страница 99: ...s 4 instead of Reserved has a power range of 12 95 25 5 W PoE Specification The port 1 24 supports the PoE function Total power The maximum power which the switch can support to the PDs Notice You must reserve about 20 W for the system That is if you connect an external power supported 740W Schedule The Switch allows user to arrange a week schedule to enable or disable the PoE for the specific por...

Страница 100: ...ic port interface poe disable enable This command enables or disables the PoE function on the specific port interface poe priority critical high low This command configures the priority of the PoE function for the specific port critical The highest priority high The middle priority low The lowest priority configure interface range gigabitethernet1 0 PORTLISTS This command enters the interface rang...

Страница 101: ...ct a port or a range of ports that you want to configure the PoE function State Select Enable to enable the PoE function on the specific port Select Disable to disable the PoE function on the specific port Priority Select Critical High Low priority for the specific port Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh PoE Mode Displays the...

Страница 102: ...tate configuration is disabled The Switch will not perform the schedule function If the global state is enabled the Switch will check every port s configurations If the port s check configuration is NO for a specific day the Switch will not perform action for the specific port If the port s check configuration is YES for a specific day the Switch will check the Start time and End Time If the curre...

Страница 103: ...s no This command enables or disables the PoE schedule on the specific day interface poe schedule week Sun Mon Tue Wed Thu Fri Sat start time VALUE end time VALUE action enable disable This command configures the PoE schedule start time and end time on a specific day on the specific port Users can enable or disable the PoE on the time period Web Configuration Parameter Description Port Selects a p...

Страница 104: ...alarm all to the Power Device depending on the port s configuration Power OFF Time sec When PD has been rebooted the PoE port restored power after the specified time Default 15 range 3 120 sec Startup Time sec When PD has been start up the Switch will wait Start up time to do PoE Auto Checking Default 60 range 30 600 sec Interval Time sec Device will send checking message to PD each interval time ...

Страница 105: ...when the system detects that the host cannot respond the keep a live probe packet Interface pd alive interval VALUE This command configures the interval to send the keep a live probe packets to check if the host is still alive for the specific port Interface pd alive ip IP_ADDR This command configures the Host IP address which connects to the specific port Interface pd alive retry time VALUE This ...

Страница 106: ...to send the packet probes to check if the host is still alive Retry Time The retry times when no response from the host for the keep a live probe packet Action The action to the Power Device when the system detects that the Power Device cannot respond the keep a live probe packet The options have Reboot Alarm All None Power Off Time When PD has been rebooted the PoE port restored power after the P...

Страница 107: ...e power delay enable disable This command enables disables of the Power Delay function for the specific port interface poe power delay time VALUE This command configures the delay time of the Power Delay for the specific port configure interface range gigabitethernet1 0 PORTLISTS This command enters the interface configure node if range poe power delay enable disable This command enables disables ...

Страница 108: ...e State Enables Disables the PoE Power Delay for the specific ports Time The delay time for the specific ports Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Power Delay Status Port The port ID State The PoE power delay state for the port Time The PoE power delay time for the port Notice The high priority port should have low value for p...

Страница 109: ...ology change In STP a longer delay is required as the device that causes a topology change first notifies the root bridge and then the root bridge notifies the network Both RSTP and STP flush unwanted learned addresses from the filtering database In STP the port states are Blocking Listening Learning Forwarding In RSTP the port states are Discarding Learning and Forwarding Note In this document ST...

Страница 110: ...f the bridge The slower the media the higher the cost How STP Works After a bridge determines the lowest cost spanning tree with STP it enables the root port and the ports that are the designated ports for connected LANs and disables all other ports that participate in STP Network packets are therefore only forwarded between enabled ports eliminating any possible network loops STP aware switches e...

Страница 111: ...y part of STP a network administrator can manually disable a port 802 1w RSTP In 1998 the IEEE with document 802 1w introduced an evolution of the Spanning Tree Protocol Rapid Spanning Tree Protocol RSTP which provides for faster spanning tree convergence after a topology change Standard IEEE 802 1D 2004 now incorporates RSTP and obsoletes STP While STP can take 30 to 50 seconds to respond to a to...

Страница 112: ... is from 1 to 200000000 Higher cost paths are more likely to be blocked by STP if a network loop is detected BPDU Guard This is a per port setting If the port is enabled in BPDU guard and receive any BPDU the port will be set to disable to avoid the error environments User must enable the port by manual BPDU Filter It is a feature to filter sending or receiving BPDUs on a switch port If the port r...

Страница 113: ...onds Hello Time 2 seconds Maximum Age 20 seconds System Priority 32768 Transmission Limit 3 seconds Per port STP state enabled Per port Priority 128 Per port Edge port disabled Per port BPDU filter disabled Per port BPDU guard disabled Per port BPDU Root guard disabled Per port Path Cost depend on port link speed Example Bandwidth STP Port Cost Value 10 Mbps 100 100 Mbps 19 1 Gbps 4 10 Gbps 2 ...

Страница 114: ...4 30 max age 6 40 hello time 1 10 This command configures the bridge times forward delay max age hello time configure no spanning tree algorithm timer This command configures the default values for forward time max age hello time configure spanning tree forward time 4 30 This command configures the bridge forward delay time sec configure no spanning tree forward time This command configures the de...

Страница 115: ...mmand configures the port priority to default for the specific port config interface range gigabitethernet1 0 PORTLISTS This command enters the interface configure node if range spanning tree disable enable This command configures enables disables the STP functions for the specific port if range spanning tree bpdufilter disable enable This command configures enables disables the bpdufilter functio...

Страница 116: ...at regular intervals Any port that ages out STP information provided in the last BPDU becomes the designated port for the attached LAN If it is a root port a new root port is selected from among the Switch ports attached to the network The allowed range is 6 to 40 seconds Hello Time This is the time interval in seconds between BPDU Bridge Protocol Data Units configuration message generations by th...

Страница 117: ...pecific port Edge Port Configures the port type for the specific port Edge or Non Edge BPDU Filter Enables Disables the BPDU filter function for the specific port BPDU Guard Enables Disables the BPDU guard function for the specific port ROOT Guard Enables Disables the BPDU root guard function for the specific port Port Status Active The state of the STP function Role The port role Should be one of...

Страница 118: ...e in seconds the Switch can wait without receiving a configuration message before attempting to reconfigure Hello Time This is the time interval in seconds at which the root switch transmits a configuration message The root bridge determines Hello Time Max Age and Forwarding Delay Forward Delay This is the time in seconds the root switch will wait before changing states Current Bridge Status MAC a...

Страница 119: ...s between BPDU Bridge Protocol Data Units configuration message generations by the root switch Forward Delay This is the maximum time in seconds the Switch will wait before changing states This delay is required because every switch must receive information about topology changes before it starts to forward frames In addition each port needs time to listen for conflicting information that would ma...

Страница 120: ...put status CLI Configuration Node Command Description enable show hardware monitor C F This command displays hardware working information CWGE10FX2TX8MSPOE show hardware monitor C Hardware Working Information Temperature C Crent MAX MIN Threshold Status BOARD 44 0 44 2 24 0 80 0 Normal CPU 49 2 49 2 26 5 80 0 Normal PHY 57 5 57 5 30 0 80 0 Normal Voltage V Current MAX MIN Threshold Status 1 0V IN ...

Страница 121: ...t Statistics This feature helps users to monitor the ports statistics to display the link up ports traffic utilization only CLI Configuration Node Command Description enable show port statistics This command displays the link up ports statistics Example CWGE10FX2TX8MSPOE show port statistics Packets Bytes Errors Drops Port Rx Tx Rx Tx Rx Tx Rx Tx 4 1154 2 108519 1188 0 0 0 0 ...

Страница 122: ...x Bytes The field displays the transmitted byte count Rx Errors The field displays the received error count Tx Errors The field displays the transmitted error count Rx Drops The field displays the received drop count Tx Drops The field displays the transmitted drop count Refresh Click this button to refresh the screen quickly Port Utilization This feature helps users to monitor the ports traffic u...

Страница 123: ...10FX2TX8MSPOE TECH SUPPORT 1 888 678 9427 Web Configuration Parameter Description Port Select a port or a range of ports to display their RMON statistics Speed The current port speed Utilization The port traffic utilization Refresh Click this button to refresh the screen quickly ...

Страница 124: ...cs CLI Configuration Node Command Description enable show rmon statistics This command displays the RMON statistics configure clear rmon statistics IFNAME This command clears one port s or all ports RMON statistics Web Configuration Parameter Description Port Select a port or a range of ports to display their RMON statistics Show Show them Clear Clear the RMON statistics for the port or a range of...

Страница 125: ...Configuration Node Command Description enable show sfp info port PORT_ID This command displays the SFP information enable show sfp ddmi port PORT_ID This command displays the SFP DDMI status Web Configuration Parameter Description Port Select a port number to configure Apply Click Apply to display the SFP information Fiber Cable To indicate if the fiber cable is connected Connector Code of optical...

Страница 126: ...port will be blocked And if the recovery function is enabled the port will be enabled after recovery time Default Settings Packet Packet Recovery Port State Status Type Rate pps State Time min 1 Disabled Normal Bcast 1000 Enabled 1 2 Disabled Normal Bcast 1000 Enabled 1 3 Disabled Normal Bcast 1000 Enabled 1 4 Disabled Normal Bcast 1000 Enabled 1 5 Disabled Normal Bcast 1000 Enabled 1 6 Disabled N...

Страница 127: ...r recovery disable enable This command enables disables the recovery function for the traffic monitor on the port interface traffic monitor recovery time 1 60 This command configures the recovery time for the traffic monitor on the port configure interface range gigabitethernet1 0 PORTLISTS This command enters the interface configure node if range traffic monitor disable enable This command enable...

Страница 128: ...ou want to configure State Enables disables the traffic monitor function on these ports Action Unblock these ports Packet Type Specify the packet type which you want to monitor Packet Rate Specify the packet rate which you want to monitor Recover State Enables disables the recovery function for the traffic monitor function on these ports Recovery Time Configures the recovery time for the traffic m...

Страница 129: ...more than one rule matches the actions and meter counters are taken from the policy associated with the matched rule with highest priority L2 ACL Support 1 Filter a specific source MAC address Command source mac host MACADDR 2 Filter a specific destination MAC address Command destination mac host MACADDR 3 Filter a range of source MAC address Command source mac MACADDR MACADDR The second MACADDR i...

Страница 130: ...tch the profile the packets will be dropped permit If packets match the profile the packets will be forwarded acl destination mac host MACADDR This command configures the destination MAC and mask for the profile acl destination mac MACADDR MACADDR This command configures the destination MAC and mask for the profile acl destination mac MACADDR MACADDR This command configures the destination MAC and...

Страница 131: ...mmand removes the UDP TCP source port from the profile acl L4 destination port PORT This command configures the UDP TCP destination port for the profile acl no l4 destination port This command removes the UDP TCP destination port from the profile acl vlan 1 4094 This command configures the VLAN for the profile acl no vlan This command removes the limitation of the VLAN from the profile acl source ...

Страница 132: ...8MSPOE config access list 111 CWGE10FX2TX8MSPOE config acl vlan 2 CWGE10FX2TX8MSPOE config acl source interface 1 CWGE10FX2TX8MSPOE config acl show Profile Name 111 Activate disabled VLAN 2 Source Interface 1 Destination MAC Address any Source MAC Address any Ethernet Type any Source IP Address any Destination IP Address any Source Application any Destination Application any ...

Страница 133: ... field is empty it means the profile will filter the one MAC configured in Source MAC field Destination MAC Configures the destination MAC of the packets that you want to filter Mask of Destination MAC Configures the bitmap mask of the destination MAC of the packets that you want to filter If the Destination MAC field has been configured and this field is empty it means the profile will filter the...

Страница 134: ...is field is empty it means the profile will filter the one IP configured in Destination IP field Source Application Configures the source UDP TCP ports of the packets that you want to filter Destination Application Configures the destination UDP TCP ports of the packets that you want to filter Source Interface s Configures one or a rage of the source interfaces of the packets that you want to filt...

Страница 135: ...work Management Protocol RFC 1213 MIB II RFC 1493 Bridge MIB RFC 1643 Ethernet Interface MIB RFC 1757 RMON Group 1 2 3 9 SNMP community act like passwords and are used to define the security parameters of SNMP clients in an SNMP v1 and SNMP v2c environments The default SNMP community is public for both SNMP v1 and SNMP v2c before SNMP v3 is enabled Once SNMP v3 is enabled the communities of SNMP v...

Страница 136: ...sables enables the SNMP on the switch configure snmp system contact STRING This command configures contact information for the system configure snmp system location STRING This command configures the location information for the system configure snmp system name STRING This command configures a name for the system The System Name is same as the host name configure snmp trap receiver IPADDR VERSION...

Страница 137: ...ect Enable to activate SNMP on the Switch Select Disable to not use SNMP on the Switch System Name Type a System Name for the Switch The System Name is same as the host name System Location Type a System Location for the Switch System Contact Type a System Contact for the Switch Apply Click Apply to configure the settings Refresh Click this button to reset the fields to the last setting ...

Страница 138: ...dit MIBs configure settings on the Switch Network ID of Trusted Host Type the IP address of the remote SNMP management station in dotted decimal notation for example 192 168 1 0 Mask Type the subnet mask for the IP address of the remote SNMP management station in dotted decimal notation for example 255 255 255 0 Apply Click Apply to configure the settings Refresh Click Refresh to begin configuring...

Страница 139: ... Management Protocol to use v1 or v2c Community String Specify the community string used with this remote trap station Apply Click Apply to configure the settings Refresh Click Refresh to begin configuring this screen afresh Trap Receiver List No This field displays the index number of the trap receiver entry Click the number to modify the entry IP Address This field displays the IP address of the...

Страница 140: ...down Configuration Change The system configurations in the NV RAM have been updated Firmware Upgrade The system firmware image has been updated User Login A user login the system Port Blocked A port is blocked by looping detection or BPDU Guard Default Settings Mail Alarm Configuration State Disabled Server IP 0 0 0 0 Server Port 25 Mail From Mail To Trap Event Status System Reboot Disabled Port L...

Страница 141: ...Server Outgoing Messages smtp gmail com SSL 465 smtp gmail com StartTLS 587 POP3 Server Incoming Messages pop gmail com SSL 995 Outlook com Server Authentication Port SMTP Server Outgoing Messages smtp live com StartTLS 587 POP3 Server Incoming Messages pop3 live com SSL 995 Yahoo Mail Server Authentication Port SMTP Server Outgoing Messages smtp mail yahoo com SSL 465 POP3 Server Incoming Message...

Страница 142: ...rver authentication account configure mail alarm mail from This command configures the mail sender configure mail alarm mail to This command configures the mail receiver configure mail alarm server ip IPADDR server port VALUE This command configures the mail server IP address and the TCP port configure mail alarm server ip IPADDR server port Default This command configures the mail server IP addre...

Страница 143: ...ate Enable disable the Mail Alarm function Server IP Specifies the mail server s IP address Server Port Specifies the TCP port for the SMTP Account Name Specifies the mail account name Account Password Specifies the mail account password Mail From Specifies the mail sender Mail To Specifies the mail receiver Trap State Enables disables the mail trap event states ...

Страница 144: ...URL PATH can be ftp user pass 192 168 1 1 file http 192 168 1 1 file tftp 192 168 1 1 file configure archive upload config URL PATH This command uploads the current configurations file to a TFTP server configure archive download fw URL PATH This command downloads a new copy of firmware file from TFTP FTP HTTP server Where URL PATH can be ftp user pass 192 168 1 1 file http 192 168 1 1 file tftp 19...

Страница 145: ...n Configuration Save Configurations Press the Save button to save the current settings to the NV RAM flash Upload Download Configurations to from a your server Follow the steps below to save the configuration file to a your PC Select the Press Download to save configurations file to your PC Click the Download button to start the process ...

Страница 146: ...button to set the settings to factory default configurations The Configuration Status Display the configuration status of recorded in the NV RAM Note If the user has changed any configurations the message display The configurations have been modified otherwise The message The configurations are default values There are two conditions will change message from The configurations have been modified t...

Страница 147: ...witch in the File path text box or click Browse to locate it Click Upgrade to load the new firmware Reboot Reboot allows you to restart the Switch without physically turning the power off Follow the steps below to reboot the Switch The following screen requests confirmation Click OK again and then wait for the Switch to restart This takes up to two minutes This does not affect the Switch s configu...

Страница 148: ...This command disables the http on the Switch configure http server port VALUE This command configures the TCP port for the HTTP server configure no http server port This command resets the HTTP TCP port to 80 configure ssh server This command enables the ssh on the Switch configure no ssh server This command disables the ssh on the Switch configure telnet server This command enables the telnet on ...

Страница 149: ...Telnet Server State Selects Enable or Disable to enable or disable the Telnet service TELNET Server TCP Port Configures the TCP port for the Telnet service Apply Click Apply to configure the settings Refresh Click this button to reset the fields to the last setting Server Status HTTP Server Status Displays the current HTTP service status HTTP Server TCP Port Displays the current TCP port of the HT...

Страница 150: ...KB size If the file is full the oldest one will be replaced CLI Configuration Node Command Description enable show syslog The command displays the entire log message recorded in the Switch enable show syslog level 1 6 The command displays the log message with the LEVEL recorded in the Switch enable show syslog server The command displays the syslog server configurations configure clear syslog The ...

Страница 151: ...t Enable to activate switch sent log message to Syslog server when any new log message occurred Facility Selects the facility level Apply Click Apply to add modify the settings Refresh Click Refresh to begin configuring this screen afresh Log Level Select Alert Critical Error Warning Notice Information to choose which log message to want to see Clear Click Clear to clear all of log message Save Cl...

Страница 152: ...t to enter the Switch and then create a new user account Default Settings Maximum user account 6 Maximum user name length 32 Maximum password length 32 Default user account for privileged mode admin admin Note The Switch allows users to create up to 6 user account The user name and the password should be the combination of the digit or the alphabet The last admin user account cannot be deleted The...

Страница 153: ...rs User Authority Select with which group the user associates admin read and write or normal read only for this user account Apply Click Apply to add modify the user account Refresh Click Refresh to begin configuring this screen afresh User Account List No This field displays the index number of an entry User Name This field displays the name of a user account User Authority This field displays th...

Страница 154: ...ime Email ComNet Global Service Center customercare comnet net 2021 Communication Networks Corporation All Rights Reserved ComNet and the ComNet Logo are registered trademarks of Communication Networks LLC 3 CORPORATE DRIVE DANBURY CT 06810 USA T 203 796 5300 F 203 796 5303 TECH SUPPORT 1 888 678 9427 INFO COMNET NET SUITE 7 CASTLEGATE BUSINESS PARK CALDICOT SOUTH WALES UK NP26 5AD T 44 0 2036 300...

Отзывы: