ADCP-96-040 • Rev D • January 2018
Page 7
© 2018, CommScope, Inc.
Figure 4. MST Cable Coiled and MST Placed in a Box
Figure 5. Distribution Cable on a Spool
The MST may be equipped with
standard
flat drop cable,
armored
round drop cable,
or
Realflex
flat drop cable (Rapid MST). Observe the following minimum bend radius
limits and pull force limit when routing and installing the MST cable:
Standard
Flat
Drop
Cable:
Maintain a minimum bend radius of
15 cm
(6 inches)
during installation and
10 cm
(4 inches) when installed.
Armored Round Drop Cable
: Maintain a minimum bend radius of
18.2 cm
(7.2
inches) during installation and
9.1 cm
(3.6 inches) when installed.
23160-B
FOUR MST’S
PER TRAY
TWO MST’S
PER TRAY
ONE MST
PER TRAY
* REMOVE #6-32 SCREWS FROM FANOUT
ASSEMBIES THAT NEED TO BE MOVED
TO THE FRONT OF THE PANEL
24617-A
SEE DETAIL A
DETAIL A
*REMOVE SCREWS FROM BOTH
SIDES OF CHASSIS. WHEN
REINSTALLING TIGHTEN TO
6 INCH-LBS (0.7 Nm) OF TORQUE.