3. Insert a dry swab into the adapter as shown in
Figure 20
.
4. While applying
light pressure
against the connector end-face, rotate the dry
swab 360º three times.
5. Dispose of the dry swab after use.
6. When the connector end-face and adapter ferrule are clean, reinstall the optical
port dust cap and tighten using the 216B key tool.
Figure 20. Cleaning Optical Port Connector and Adapter
7.3
O-Ring Lubrication
The O-rings used on the hardened connector and on the optical port dust cap are
lubricated when shipped from the factory to prevent damage during installation. If the
O-rings become excessively dry, they may require additional lubrication to prevent
damage. Remove the O-rings from the connector or dust cap and apply a small
amount of lubricant directly to each ring. Then reinstall the O-rings on the connector or
dust cap. Apply only the recommended O-ring lubricant (MST-ACC-LUBE1).
7.4
Internal Connector Replacement - 2xN Style MST
Opening the MST enclosure is not recommended except to replace a damaged optical
connector. If an internal repair is required to a 2xN style MST, order the MST Connector
Note:
Do not apply alcohol to the swab or the adapter.
20397-A
ROTATE SWAB