ADCP-96-040 • Rev D • January 2018
Page 6
© 2018, CommScope, Inc.
• Splicing equipment (MST with stub cable)
• Appropriate fasteners to mount the UMB and tools to install the fasteners
• Note: If using an enclosure such as a hand-hole or pedestal, refer to the
instructions provided with the enclosure for any additional tools or equipment
required
2.3
Unpacking and Inspection
This section provides instructions for opening the shipping boxes, verifying that all
parts have been received, and verifying that no shipping damage has occurred.
Use the following procedure to unpack and inspect the MST and all accessories:
1. Open the shipping carton(s) and carefully inspect the MST and the attached
cable.
2. If there are damages, contact CommScope (see
Topic 8 on page 20
) for an RMA
(Return Material Authorization) and to reorder if replacement is required.
3
GENERAL INSTALLATION INFORMATION
This section provides general installation information for all versions of the MST.
3.1
Cable Handling Recommendations
Each MST is equipped with a cable. Depending on the length of the cable and the
number of ports on the MST enclosure, the MST cable may be coiled up and placed in
box or it may be wound on a spool. Use the following cable handling procedures when
removing the cable from the packaging materials:
MST In a Box:
If the MST is placed in a box with other MST’s, carefully remove the
packaging material to expose the cable coil and the MST as shown in
Figure 4
. Leave
the MST on top and in the center of the coil. If the MST was ordered with the
standard
coiled cable option, uncoil the cable starting with the
stub or connector
. If the MST
was ordered with the
reverse
coiled cable option, uncoil the cable starting with the
MST
.
MST on a Spool:
If the MST is mounted on a spool, remove the spool assembly from
the box as shown in
Figure 5
. Leave the MST on top of the spool and place the spool
on a vertical arbor or carousel. If the MST was ordered with the
standard
coiled cable
option, uncoil the cable starting with the
stub or connector
. If the MST was ordered
with the
reverse
coiled cable option, uncoil the cable starting with the
MST
.
Note:
If installing a Rapid MST, refer to the instruction sheet provided with the
spool for additional procedures for unwinding and routing the cable, removing the
MST from the spool, and storing the excess cable slack.