6. Maintenance
User’s Manual for ION
®
-U Page
53
6.3. Cleaning the Heat Sink
Note:
Read and observe chapter 1.2 Health and Safety as well as the
instructions in chapter 6.1 General
before starting with the replacement
procedure. Then, proceed as follows:
1. Switch off the Remote Unit. Make sure that mains power is disconnected for the
following procedure.
2. Remove the fan cover and fan unit from the Remote Unit as described in chapter
6.2 Replacing the Fan Unit.
Caution
: Risk of injury by flying particles when compressed air is used. Wear
protective clothing, especially protective glasses.
3. Use compressed air (max. 5 bars) to blow out any dust, dirt, or other debris in the
heat sink from back to front.
4. If the dirt cannot be blown out completely and parts of it stick to the ribs of the
heat sink, clean the parts concerned carefully from the front using e.g. a brush.
Take care that the heat sink material is not scratched or damaged.
5. After cleaning the heat sink, remount the fan unit according to chapter 6.2
Replacing the Fan Unit. Then, switch the Remote Unit back on.