![CommScope ION-U EU H 7P/80-85P/17EP/19P DC Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/commscope/ion-u-eu-h-7p-80-85p-17ep-19p-dc/ion-u-eu-h-7p-80-85p-17ep-19p-dc_manual_2643787018.webp)
4. Commissioning
Page 18
User’s Manual for ION
®
-U
5. Notice
: Ensure that there is free access to the electrical connections as well as
to the cabinet. The approved bending radius of the connected cables must not be
exceeded. See chapter 7.1 for more details.
6. Notice
: If any different or additional mounting material is used, ensure that the
mounting remains as safe as the mounting designed by the manufacturer. The
specifications for stationary use of the Remote Unit must not be exceeded.
Ensure that the static and dynamic strengths are adequate for the environmental
conditions of the site. The mounting itself must not vibrate, swing or move in any
way that might cause damage to the Remote Unit.
7. Notice
: Observe all additional rules or restrictions regarding mounting that apply
to specific Remote Unit types. For details refer to the mechanical specifications in
the data sheet for the unit. Install the unit vertically with the fan unit at the top. A
maximum tilt angle of 25° from a vertical position must be maintained, as shown
in the following illustrations:
8. Notice
: A spacing of 50 mm (1.97 inch) around the unit is required.
9. Notice
: To ensure sufficient airflow when mounting the unit in enclosed spaces,
two lid openings (one for the air inlet and the other for the air outlet) must be
provided. Do not block these air inlets and outlets when mounting the Remote
Unit. The size of each opening must equal at least 18 x 18 cm (> 300 cm
2
).
Ensure that there is no thermal short circuit between the air inlet and air outlet.
Make sure free airflow is not deflected or otherwise obstructed.
Specified torques must be observed for certain mounting procedures according to the
following table:
Type
Tallow-drop
screws
Hex
nuts
Screw
band lock
Spacing
bolts
PG
(plastic)
PG
(alum.)
Thread
M 4
M 8
M 4
M 8
PG 13.5
PG 29
Specified
torques
3.3 N-m
27 N-m
6 N-m
2.3 N-m 27 N-m 3.75 N-m 10 N-m
table 4-1 Specified torques